Welcome Customer !

Membership

Help

Anhui Huarun Instrument Cable Co., Ltd
Custom manufacturer

Main Products:

ybzhan>News

Anhui Huarun Instrument Cable Co., Ltd

  • E-mail

    18655421@qq.com

  • Phone

    15255082530

  • Address

    No.1 Weisan Avenue, Tongcheng Industrial Park, Tianchang City, Anhui Province

Contact Now
Anhui Huarun thermocouple compensation wire and compensation cable
Date: 2013-07-24Read: 10

Product standards for thermocouple compensation wires and cables: GB/T4989-94 and JB/T7495-94 standards are adopted.

1. Application of thermocouple compensation wire and compensation cable:

Thermocouples use (high temperature resistant) compensating wires and cables, which are a pair of insulated wires with the same nominal value as the matching thermoelectric potential within a certain temperature range (including high temperature and room temperature). They are used to connect thermocouples and measuring devices to compensate for the errors caused by temperature changes at the connection between them and thermocouples. This product is suitable for electrical connection between various thermocouples with scale marks of S, K, E, T, J, N and temperature display instruments to improve measurement accuracy.

2: Thermocouple compensation wire and compensation cable usage conditions:

(1) Working temperature: heat-resistant, available in two types: 200 ℃ and 260 ℃;

Generally used: maximum temperature of 70 ℃ and 105 ℃.

(2) Zui low ambient temperature: Fluoroplastic insulated and sheathed cables: fixed laying -60 ℃, non fixed laying -20 ℃;

Polyvinyl chloride insulated and sheathed cables: fixed installation at -40 ℃, non fixed installation at -15 ℃.

(3) The minimum bending radius for PVC insulated and sheathed non armored cables is not less than 6 times the outer diameter of the cable, for fluoroplastic insulated and sheathed non armored cables it is not less than 10 times the outer diameter of the cable, and for armored cables it is not less than 12 times the outer diameter of the cable.