APES-LNH3 (1K) gas detector detailed introduction
Date: 2024-06-21Read: 11

APES-LNH3 (1K) gas detector detailed introduction

Intelligent handheld pump suction ammonia gas detector model: APES-LNH3 (1K)


Product Name
Intelligent handheld pump suction ammonia gas detector
Product Model
APES-LNH3(1K)
gas detection
ammoniaNH3
Wireless data interface
supportGPRS/ZIGBEE (optional)
Selection of detection range
0-1000 ppm
data recovery
One click restore to factory default settings , convenient and fast , Don't worry about misoperation
resolution
1PPM
Automatic diagnosis
System check : Battery level , Display , sensors , hardware failure Users can set alarm values
adoption method
Pump suction (stable airflow) Stabilize the air chamber pressure Check for greater stability , more precise )
storage capacity
100000 pieces, optional 1 time/1 second, 1 time/10 seconds, 1 time/60 seconds
display mode
HDOLED LCD backlit display
Air pump flow rate
200~300ml/min
detection accuracy
≤± 3% FS (ordinary type) ≤± 1% FS (high precision)
zero drift
≤± 2% (F.S/year)
repetitiveness
≦±1%
Explosion proof type
intrinsically safe
alarm point
You can set it yourself
Explosion-proof marking
EXiaⅡCT4
alarm method
sound(≤ 75 decibels), light
Protection level
IP65
temperature compensation
temperature-compensated
weight
360g
response time
T90≤30S
execution standard
GB15322.1-2003,GB3836.1-2010 GB3836.2-2010,GB3836.4-2010
recovery time
Determined by the principle and range of the sensor
Overall dimensions
132 × 73 × 45mm(L × W × H) ; 15cm (deformable suction pipe length)
working power supply
Built in high-capacity lithium battery
Operating Temperature
-40℃ ~ 50℃
battery capacity
2800mA
Operating Humidity
0-95% RH
Continuous working hours
≥ 24 hours, determined by the principle of the sensor
pressure range
1 ± 10% atmospheric pressure
Sensor lifespan
Determined by the principle of sensors ,
Standard Appendix
Instruction manual, charger, aluminum packaging box, certificate of conformity Warranty card Factory Test Report
Wired data interface
USB1.1