code name

Parameter meaning

Instructions

Set range

default

AL1

call the police1parameter

call the police1Temperature control point for relay operation

0- Full range

5

AL2

call the police2parameter

call the police2Temperature control point for relay operation

0- Full range

10

FAL

Alarm point hysteresis

Alarm output action insensitive area

0- Full range

1

P

proportional band

ifP=0It is positional control.PThe instrument is a proportional output type when the value is not zeroPIDControl,PFor dynamic working range.

1℃-200℃

20

Hyc

Main output hysteresis

Main output action insensitive area(P=0(Appears)

0-50℃

2

I

Integral time constant

Eliminating static errors and the intensity of instrument control over output energy.IThe smaller the value, the stronger the control ability.

0-999 seconds

200

D

Differential time constant

Pre adjustment capability refers to the speed at which the output energy is regulated when the measured value changes.DHigh value, fast response

0-999 seconds

50

T

Proportional cycle

The total heating and termination time is one cycle. The instrument controls the output power by adjusting the heating and terminal control

1-200 seconds

20

Sc

Measurement value bias

Sensor error correction

±19.9

0

At

auto-adaptation

The process of automatically selecting appropriate control parameters for instruments

0 levels/1open

0

EP

Proportional band offset

Used to prevent temperature overshoot of instruments after cold start

10

10

Lck

Parameter lock

0: Not locked;1Lock the inner layer parameters;

2: Lock all parameters

0-2

0