Metal tube rotor flowmeter is suitable for high temperature, high pressure, and highly corrosive media; Can be used in flammable and explosive hazardous environments; Optional two-wire system, battery, and AC power supply methods; Multi parameter calibration function; Equipped with data recovery, data backup, and power down protection functions.
the vast majority
Metal tube rotor flowmeterIt must be installed vertically on a vibration free pipeline without obvious inclination, and the fluid should flow from bottom to top. To maintain continuous flow, Figure 6 shows an example of a pipeline connection with a bypass piping system. The angle between the centerline and the plumb line of a floating flowmeter usually does not exceed 5 degrees, with a high precision of θ ≤ 20 ° (above level 1.5). If θ=12 °, the additional error is 1%. There is no strict length requirement for the upstream straight pipe section of the dashboard, but the manufacturer also requires a length of (2-5) D, which is actually unnecessary.