Main parameters of impact machine
work platform
500×500 mm
Load 15KG
Peak acceleration half sine wave: 20-600 G
Pulse duration half sine: 1-30ms
Equipment size 1300 × 1450 × 2550mm
The total weight of the equipment is 1300 kg
measurement system
Input channel 2
Sampling frequency 192KHz
Voltage range -10V -+10V coupling mode
AC/DC/ICP pulse duration
0.5-100ms acceleration
5000G communication interface
USB 2.0 supports standards
ISO,MIL-STD-810, User defined standards
Operating System Microsoft Win7/10 System Acceleration Sensor
Output method: Charge based
Sensitivity 3.93pC/g
Frequency range 0.5-12KHz
Acceleration range ± 2500G
Working environment -40~+160 ℃
Other instructions
Power supply AC 3-phase 380V ± 10% 5KVA
Compressed air 0.5-0.8Mpa
Temperature RT~40 ℃
Humidity 25 ℃ < 85RH%
Verification standards
JJG541-2005
3. Introduction to Equipment Features
3.1 Work Platform
Adopting high-strength imported aluminum alloy work platform
3.2 Height control for lifting and lowering
The elevated height is measured by a photoelectric encoder component installed on the base, which has high accuracy in measurement
Strong anti-interference ability and high reliability ensure the repeatability of impact.
3.3 Braking System
Adopting gas-liquid pressurization and strong friction holding brake to prevent secondary impact braking function can quickly and reliably brake, preventing secondary impact
rebound
3.4 Buffer System
In order to reduce the impact force of the impact testing machine on the ground, a self buffering system was designed for the impact testing machine, which consists of a large mass base
Composed of dampers and airbags. The vibration reduction system can reduce the impact force transmitted from the work platform to the ground and the impact waveform
It has a good high-frequency filtering effect, making the impulse waveform smoother.
3.5 Waveform Generator
Half sine wave: rubber pad
3.6 Safety devices
Emergency stop switch: cuts off the circuit in emergency situations such as forcibly disconnecting the contact fusion of the action mechanism, in compliance with
EN418 with
There are insurance institutions to prevent misoperation.
3.7 Introduction and Characteristics of Impact Measurement System
The impact measurement analysis control instrument is a high-quality dynamic measurement, dynamic analysis, and control system based on DSP structure.
3.7.1 High cost performance ratio and reliability
The hardware adopts modular and low-noise design technology, and the hardware circuits for control and measurement analysis functions are all placed in the interface box
In China, independent of the computer, USB2.0 is used to communicate between the interface box and the PC.
3.7.2 High measurement accuracy
Adopting high-performance floating-point DSP processing structure, 24 bit resolution ADC/DAC, combined with high-precision floating-point digital filtering
Wave and low-noise design technology.
Complete automatic safety detection and protection functions, high test safety, equipped with manual emergency interruption, impact table limit
Complete safety measures such as parameter settings and rationality ensure the safe operation of the experiment.
3.7.3 Diverse operating methods
Manual, semi-automatic, and fully automatic cyclic operation modes can be used.
3.7.4. Flexible and diverse input methods: charge ICP
The interface box is equipped with a charge amplifier, which can be directly connected to a charge type accelerometer; And built-in ICP constant current
The source can be directly connected to the ICP sensor.
3.7.5. Application software based on Win2000/NT/XP, easy to operate
Measurement and control are implemented by DSP, making PC software only responsible for user interaction and display, truly realizing Windows
The multi tasking mechanism and graphical interface make it easy for users to operate and display in various forms.
3.7.6. Automatically generate WORD test report
During and after the experiment, Microsoft Word test reports can be automatically or manually generated, and users can
Define report content.
3.7.7 Control Characteristics
Digital control of height, high precision, and good repeatability;
Automatic drop height calculation and control;
Power on self-test, automatically saving operation records;
Provide rebound control without secondary impact;
The system provides alarm function;
3.7.8 Characteristics of Testing System:
Compliant with MIL-STD-810, GJB-150-18-86, IEC68-2-27 standards, DELL standards
Range: 0.1V, 1V, 10V;
The sampling frequency can reach 1MHz
Signal conditioning: analog filters and 160Db/Octave digital anti aliasing filters;
Measurement method: Multi frame waveform recording and playback;
Test acceleration 100000gn
Minimum test pulse width 0.1ms
Support internal and external triggering
Frame length: 512102420484096819216384;
Time domain analysis: shock wave automatic alignment, automatic tolerance band detection, peak acceleration, pulse width, velocity change, etc
testing;
Shock response spectrum analysis: logarithmic resolution 1/1, 1/3, 1/6, 1/12, 1/24 octave band analysis, adjusting impedance
Ni coefficient and Q (quality factor) value, independently adjust the lower limit, upper limit, and reference frequency;
Automatically generate test reports
3.7.9 Analysis Function:
Transient capture of shock waveform
Transient capture helps you obtain single or multiple pulses, and the system automatically analyzes the peak value, pulse width, velocity change, head injury index (HIC), and other data of the impact pulse. It automatically matches the captured pulse waveform to the ideal waveform and compares the two
The deviation
Shock response spectrum analysis
The impact response spectrum analysis can evaluate the potential damage caused by impact and provide a basis for designing the impact resistance of products. The system performs SRS analysis on each shock pulse and compares the deviation between the actual SRS and the target SRS.