Korean LabTech IncubatorUsage steps

1. The incubator should be placed in a clean, tidy, dry, and ventilated workspace.

2. Before use, all control switches on the panel should be in a non working state.

3. Place the test samples on the cultivation rack, and maintain appropriate spacing between each test bottle (or vessel) to facilitate the circulation of cold (hot) air convection.

4. Connect the external power supply, place the power switch in the "on" position, and the indicator light will turn on.

5. Select the cultivation temperature.

  
Korean LabTech Incubatorset temperature

Press the SET key to set the temperature. Press the SET key until the data in the lower row of the digital tube flashes, indicating that the instrument has entered the temperature setting state. Press the △ key to increase the set value, press the ▽ key to decrease the set value, and then press the SET key again to return to normal operation. The temperature setting is complete.

  
Korean LabTech Incubatorerror correction

When confirming that the value displayed on the instrument is not the correct measurement value, the displayed value can be corrected. Press the SET key for 3 seconds to enter the inner menu of the instrument panel. After selecting parameter SC, use the △ or ▽ keys to modify this parameter. The range for correcting sensor errors is+50 to -50. After the correction is complete, press the SET button for 3 seconds to exit. The correction value of the instrument is 0 when it leaves the factory. When using it, it is necessary to prevent the instrument that displays correctly from being corrected to incorrect.

  
Korean LabTech IncubatorStart self-tuning

  Korean LabTech IncubatorIt can adapt to the vast majority of control systems, and can only start self-tuning when the control effect is particularly unsatisfactory. Press the SET button for 3 seconds to enter the inner menu of the instrument, select the parameter At, and use the △ or ▽ button to start self-tuning. At this time, the At indicator light starts flashing, and the instrument enters the automatic tuning parameter working state. The instrument controls the heating system to fluctuate twice near the set point. When the At light goes out, self-tuning ends, and the new PID parameters are locked in the chip.