This morning, a customer from Hunan called to purchase an integrated temperature transmitter with a flange DN25 PN1.6, insertion depth of 300mm, -30~100 ℃, display, output of 4~20mA, material 304 lined with PTFE, rod diameter of 16mm, and a requirement of 50 units. The customer saw our company's integrated temperature transmitter in the neighboring sister unit factory before and has been using it for several years. The on-site meter display and remote control display are both very accurate, and the response is also very fast. That's why they contacted our manufacturer. Today, we will talk about the purpose of the integrated temperature transmitter product.
Firstly, integrated temperature transmitters are usually used in conjunction with display instruments, recording instruments, electronic computers, etc. They output 4-20mA and directly measure the gas quality of liquids, vapors, and solid surface temperatures in the range of -200 ℃ -1300 ℃ in the presence of carbon and chlorine compounds in the production site. This product has a two-wire output of 4-20mA and strong anti-interference ability; Save the cost of compensating wires and installing temperature transmitters; Safe and reliable, with a long service life; Cold end temperature automatic compensation, non-linear correction circuit;
Secondly, the integrated temperature transmitter is divided into explosion-proof thermocouples that utilize the principle of gap explosion-proof. When an explosion occurs inside the chamber, it can be extinguished and cooled through the gap between the joint surfaces, preventing the full temperature of the flame after the explosion from being transmitted outside the chamber, thus achieving explosion-proof.
Thirdly, the integrated temperature transmitter is divided into a thermocouple (thermistor) that generates an unbalanced signal through the temperature transmitter's bridge, which is amplified and converted into a 4-20mA DC electrical signal for the working instrument to display the corresponding temperature value.
Fourth, Main Technical Parameters
1. Temperature measurement range: -200~600C
2. Output signal: 4~20mA
3. Load resistance: ≤ 5002
4. Power supply: 24V DC
5. Power consumption: ≤ 0.5W
6. Long term stability: better than 0.2%/year (temperature coefficient of conventional products: ≤ 0.05%/C)
7. Output method: Two line system
8. Accuracy level:
Temperature transmitter accuracy level: 0.1 0.2 0.5
Display accuracy level: Analog indicator 2.5 level; Digital display level 0.5
9. Power supply: 24V DC ± 10 ℅
10. Protection level: IP65
11. Explosion proof grade:
Explosion proof type: d Ⅱ BT4 d Ⅱ CT5 d Ⅱ CT6
Intrinsic safety type: ia Ⅱ CT6
12. Insulation resistance: The insulation resistance between the instrument output terminal and the housing should not be less than 50
13. Thermal response time:
When there is a step change in temperature, the time required for the current output signal of the instrument to change to 50% of the step change is usually represented by t0.5. When the step response stabilization time of the temperature transmitter does not exceed one-fifth of the thermocouple (resistance) thermal response stabilization time t0.5, the thermocouple (resistance) thermal response time is used as the thermal response time of the instrument; When the step thermal response stability time of the temperature transmitter does not exceed half of the thermocouple (resistance) thermal response stability time t0.5, the thermal response time of the temperature transmitter is used as the thermal response time of the instrument;
14. Basic error:
The basic error of the instrument should not exceed the combined error of the basic errors of the thermocouple (resistor) and temperature transmitter.
15. Work environment:
Installation site level Temperature ℃ Relative humidity% Atmospheric pressure KPa
Cx1 -25-+55 5-95 86-106 Cx2 -25-+70 Cx3 -40-+80
Fifth, Technical Requirements:
1. The integrated temperature transmitter can communicate with the upper computer through a HART modem or remotely manage, configure, monitor variables, calibrate, and maintain the model, scale, and range of the transmitter through handheld devices and PCs;
2. The display direction of the transmitter can be adjusted according to the actual needs of the user, and the temperature of the medium measured by the transmitter, changes in sensor values, output current, and percentage can be displayed;
3. Adopting silicone rubber or epoxy resin sealing structure, it is shock resistant, moisture resistant, and suitable for installation and use in harsh on-site environments.
4. Installed on-site in junction boxes for thermocouples and thermal resistors, directly outputting 4-20mA and 0-10mA output signals. This not only saves expensive compensation wire costs, but also improves the anti-interference ability during long-distance signal transmission;
5. The thermocouple transmitter has an automatic compensation function for cold junction temperature;
6. High precision, low power consumption, wide temperature range for use, stable and reliable operation;
7. Widely applicable, it can form an integrated on-site installation structure with thermocouples and thermistors, and can also be installed as a functional module in detection equipment and instrument panels for use;
Last Article: Selection requirements for on-site pressure gauge products