The stainless steel online concentration meter can monitor the solute concentration in liquid in real time, ensuring product quality and stability of the production process. It is crucial to master the correct installation and usage methods in order to fully utilize its functionality. This article will provide a detailed introduction to the correct use of stainless steel online concentration meters.

1、 Correct installation steps
straight pipe section requirements
In order to obtain accurate measurement results, there should be sufficient straight pipe length before and after the sensor. It is usually recommended to have a straight pipe section with at least 5 times the diameter of the pipeline upstream and a straight pipe section with at least 3 times the diameter of the pipeline downstream. This can reduce the impact of fluid disturbance on the measurement.
Installation direction
Select the appropriate installation direction based on the characteristics of the medium. For applications containing suspended particles or viscous liquids, it is recommended to use a vertical installation method to allow the fluid to flow from bottom to top and prevent sediment accumulation. For cleaning liquids, horizontal installation is also a common choice.
Sealing treatment
During the installation process, attention should be paid to sealing treatment to ensure no leakage. Especially in high-pressure or highly corrosive environments, suitable sealing materials should be selected and the sealing effect should be checked regularly.
2、 Daily operation and calibration
Pre startup inspection
Before starting the stainless steel online concentration meter, it is necessary to check whether the power connection is correct and whether the grounding is good. Simultaneously confirm that there is no foreign object blockage inside the sensor and that the pipeline is filled with the fluid to be measured.
Parameter Settings
Reasonably set the various parameters of the converter according to actual application requirements, including unit system, output signal type, alarm limit, etc. Some advanced features such as cumulative total record and historical data query also need to be configured according to specific situations.
periodic calibration
To ensure long-term accuracy, it is recommended to calibrate the stainless steel online concentration meter every six months to one year. You can contact the manufacturer or authorized service agency for professional calibration, or use standard solutions for on-site comparison and calibration.