Kaitel Air Bomb Oxygen Bomb Aging Test Chamber Signed Contract with Yongqiang Cable Testing Laboratory
Date: 2020-10-28Read: 9

Kaitel Air Bomb Oxygen Bomb Aging Test Chamber Signed Contract with Yongqiang Cable Testing Laboratory
Yongqiang Cable Co., LtdIt mainly produces power cables, overhead crane cables, crane wires and cables, handle wires, water pump wires, electrical wires and cables, etc.
In order to better control the quality of aging tests for raw materials in cable production, we have signed an air bomb oxygen bomb aging test box with Keitel.
The K-WLKY air bomb oxygen bomb aging test chamber is suitable for conducting aging tests on wires, cables, rubber (plastic, synthetic leather) sheaths and insulation layers, as well as other polymer materials under specified pressure and temperature conditions in oxygen and compressed air media. By using a time controller, the constant temperature time can be set to meet the experimental requirements of different samples.
The oxygen used in the experiment should be industrial oxygen with a purity of not less than 97%. The oxygen bomb test temperature is 70 ℃ and the pressure is 2.1MPa ± 0.07. The air should be free of oil and moisture. The air bomb test temperature is 127 ℃ and the test pressure is 0.55MPa ± 0.02.
Oxygen bomb test: Connect one end of the oxygen tube (black) provided with the instrument to an oxygen cylinder with a pressure reducing valve, and directly insert the other end into the inlet of the testing machine.
Air bomb test: Connect compressed air to the air inlet of the testing machine (the instrument is equipped with a quick connector, simply plug in the air tube provided with the instrument).
When conducting an air bomb test, a pressure of 0.48Mpa can be applied without heating. When the temperature rises to 127 ℃, the pressure value will be around 0.55Mpa. Similarly, when conducting an oxygen bomb test, a pressure of 1.8Mpa can be applied without heating. When the temperature rises to 70 ℃, the pressure value will be around 2.1Mpa, and the pressure can be adjusted through intake and exhaust.
The K-WLKY air bomb oxygen bomb aging test box produced and designed by Keitel has been trusted by many cable production enterprises, provincial quality inspection laboratories, and university laboratories for teaching!
Thank you again to Yongqiang Cable Testing Laboratory for choosing the K-WLKY air bomb oxygen bomb aging test chamber.