1LA7/1LG4 Efficiency Enhanced Motor

NegotiableUpdate on 11/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The energy-saving electric motors produced by Siemens are ranked at the top of CEMEP efficiency levels "EFF1" and "EFF2". The motor with a rated frequency of 50Hz meets the requirements of IEC34-2 standard.

Product Details

Siemens Motor 1LA7/1LG4 Efficiency Enhancement Series

Clever energy-saving methods.
The energy-saving electric motors produced by Siemens are ranked at the top of CEMEP efficiency levels "EFF1" and "EFF2".
The motor with a rated frequency of 50Hz meets the requirements of IEC34-2 standard.
EFF1 (high-efficiency electric motor)
EFF2 (Efficiency Enhanced Motor)
In order to reduce the emission of CO2. Motor manufacturers comply with the requirements of CEMEP (European Committee of Electrical and Power Electronics Manufacturers). Automatically promise to distinguish electric motors based on their efficiency levels.

User and environmental benefits
By optimizing efficiency methods. Energy saving electric motors only require less energy. Still able to maintain the same power output. The improvement of efficiency is achieved by enhancing the quality of silicon steel sheets. This is achieved through the use of more effective materials (iron, copper, and aluminum) and the advancement of technology in every detail. The power loss has been reduced by nearly 45%. The benefits obtained by users are obvious: minimizing operating costs. Users save expenses day after day.

The use of energy-saving electric motors significantly reduces the impact on the environment: energy savings may reach about 20 TWh per year, which is equivalent to the power generation of 8 thermal power plants. And reduced 11 million tons of carbon dioxide emissions.

Product Selection
Model List

Siemens Motor 1LA7/1LG4 Efficiency Enhancement Series

Polar number: 2Speed: 3000rpm
Machine base size SIZE Model TYPE Rated power KW Weight KG
56 1LA7050-2AA.. 0.09 3
56 1LA7053-2AA.. 0.12 3
63 1LA7060-2AA.. 0.18 3.5
63 1LA7063-2AA.. 0.25 4.1
71 1LA7070-2AA.. 0.37 5
71 1LA7073-2AA.. 0.55 6.6
80 1LA7080-2AA.. 0.75 8.2
80 1LA7083-2AA.. 1.1 9.9
90S 1LA7090-2AA.. 1.5 12.9
90L 1LA7096-2AA.. 2.2 15.7
100L 1LA7106-2AA.. 3 22
112M 1LA7113-2AA.. 4 29
132S 1LA7130-2AA.. 5.5 41
132S 1LA7131-2AA.. 7.5 49
160M 1LA7163-2AA.. 11 69
160M 1LA7164-2AA.. 15 80
160L 1LA7166-2AA.. 18.5 93
180M 1LG4183-2AA.. 22 145
200L 1LG4206-2AA.. 30 205
200L 1LG4207-2AA.. 37 225
225M 1LG4223-2AA.. 45 285
250M 1LG4253-2AB.. 55 375
280S 1LG4280-2AB.. 75 500
280M 1LG4283-2AB.. 90 540
315S 1LG4310-2AB.. 110 720
315M 1LG4313-2AB.. 132 775
315L 1LG4316-2AB.. 160 900
315L 1LG4317-2AB.. 200 1015
Polar number: 4Speed: 1500rpm
Machine base size SIZE Model TYPE Rated power KW Weight KG
56 1LA7050-4AB. . 0.09 3
56 1LA7053-4AB. . 0.12 3
63 1LA7060-4AB. . 0.12 3.5
63 1LA7063-4AB. . 0.18 4.1
71 1LA7070-4AB. . 0.25 4.8
71 1LA7073-4AB. . 0.37 6
80 1LA7080-4AA. . 0.55 8
80 1LA7083-4AA. . 0.75 9.4
90S 1LA7090-4AA. . 1.1 12.3
90L 1LA7096-4AA. . 1.5 15.6
100L 1LA7106-4AA. . 2.2 22
100L 1LA7107-4AA. . 3 25
112M 1LA7113-4AA. . 4 31
132S 1LA7130-4AA. . 5.5 43
132M 1LA7133-4AA. . 7.5 49
160M 1LA7163-4AA. . 11 68
160L 1LA7166-4AA. . 15 93
180M 1LG4183-4AA. . 18.5 140
180L 1LG4186-4AA. . 22 155
200L 1LG4207-4AA. . 30 205
225S 1LG4220-4AA. . 37 265
225M 1LG4223-4AA. . 45 300
250M 1LG4253-4AA. . 55 390
280S 1LG4280-4AA. . 75 535
280M 1LG4283-4AA. . 90 580
315S 1LG4310-4AA. . 110 730
315M 1LG4313-4AA. . 132 810
315L 1LG4316-4AB. . 160 955
315L 1LG4317-4AB.. 200 1060
Extreme number: 6Speed: 1000rpm
Machine base size SIZE Model TYPE Rated power KW Weight KG
63 1LA7063-6AA. . 0.09 4.1
71 1LA7070-6AA. . 0.18 6.3
71 1LA7073-6AA. . 0.25 6.3
80 1LA7080-6AA. . 0.37 7.5
80 1LA7083-6AA. . 0.55 9.4
90S 1LA7090-6AA. . 0.75 12.5
90L 1LA7096-6AA. . 1.1 15.7
100L 1LA7106-6AA. . 1.5 24
112M 1LA7113-6AA. . 2.2 27
132S 1LA7130-6AA. . 3 41
132M 1LA7133-6AA. . 4 46
132M 1LA7134-6AA. . 5.5 54
160M 1LA7163-6AA. . 7.5 76
160L 1LA7166-6AA. . 11 102
180L 1LG4186-6AA. . 15 150
200L 1LG4206-6AA. . 18.5 195
200L 1LG4207-6AA. . 22 205
225M 1LG4223-6AA. . 30 280
250M 1LG4253-6AA. . 37 370
280S 1LG4280-6AA. . 45 475
280M 1LG4283-6AA. . 55 510
315S 1LG4310-6AA. . 75 685
315M 1LG4313-6AA. . 90 750
315L 1LG4316-6AB. . 110 870
315L 1LG4317-6AB. . 132 980
315L 1LG4318-6AB.. 160 1105
Special requirements
code
C13 cooling air temperature is 55 degrees Celsius, temperature assessment level F
A10 PTC is used for frequency converter alarm signals and is suitable for hazardous environments such as ZONES 2, 21, and 22
A11 3 PTC for alarm information
A12, 6 PTC sensors, 3 shutdowns, 3 alarms
A23 KTY84-130 thermistor, used for temperature indicators and over temperature protection of electric motors
Y54 Special color requirements
M72 constant speed motor is used for spark free explosion-proof, Zone 2
M73 variable frequency speed regulating motor is used for spark free explosion-proof, Zone 2
E11 German Classification Certification
E21 French Classification Certification
E31 British Classification Certification
E51 Norske Veritas certification
H57 installation encoder 1XP8001-1 (HYL)
H58 installation encoder 1XP8001-2 (HYL)
G17 installation of forced air cooling fan
H61 installation of forced air cooling fan and encoder 1XP8001
G26 installation brake
H62 installation of encoder 1XP8001 and brake
H64 installation of forced air cooling fan and encoder 1XP8001 installation of brake
The K09 junction box is on the right side (viewed from the load end)
The K10 junction box is on the left side (viewed from the load end)
K01 vibration level is R level
L27 bearing insulation
Low noise design of K37 bipolar motor
K45 moisture-proof heater, AC 230V
B02 Factory Inspection Report
Order Number Voltage Code Description
Second to last place
Voltage code
220VD/380VY 380VD/660VY Abnormal voltage frequency
1 6 9
Installation Method Code Description
the last one
Structural form code
With feet, unable to land B3 (horizontal) Without footings, with flange B5 (vertical) With feet, equipped with flange B35 (both vertical and horizontal) Without footings, with flanges and rain cover