The 401 series diffusion silicon transmitter selects imported high-performance isolated diffusion silicon sensors and adopts advanced manufacturing processes internationally. It has the same robustness and reliability as similar imported transmitters and is suitable for detecting gauge pressure, absolute pressure, and negative pressure of corrosive media in various industrial fields.
Main technical parameters
※ Power supply: 24VDC output 4-20mA two-wire system
※ Adjustable range of zero position:±5%F . S
Range adjustment ratio: 3:1 or above
Range: -100KPa~0~60MPa
Explosion proof type d II BT4, intrinsically safe type ia I1 CT5
Overpressure limit: 2 times the upper limit pressure
※ Temperature range: Process: -20~60C
※ Accuracy level:±0.2%. ±0. 5%
Stability:+0.2%
Weight: Approximately 1kg
※ Load characteristics: The load maintains a constant current output within 0-600Q (24VDC power supply)
feature
※ Direct installation during the process
※ Good temperature characteristics
※ High comprehensive accuracy
Install the attachment
Install bracket ..........G
Explosion proof cable sealing sleeve
External thread M20x1.5...... T2
If the user selects an attachment, please indicate the code of the attachment in parentheses after the selection code