YSI 55 dissolved oxygen and temperature measuring instrument:
·Handheld operation, can also be hung on the shoulder or waist
·Stainless steel probe, capable of withstanding more severe field conditions; Additionally, the weight of the metal makes it easier for the probe to sink into the water
·Available in three cable lengths of 3.7 meters, 7.5 meters, and 15 meters for selection
·Full button calibration and operation, all operations are controlled by a microprocessor
·Simultaneously display dissolved oxygen and temperature readings, with the option to display air saturation or milligrams per liter concentration
·Can directly input salinity to compensate for the deviation of dissolved oxygen in different water bodies
·Height can be directly input to compensate for the deviation of dissolved oxygen caused by air pressure at different heights
·The cable joint is equipped with a stress reliever to reduce material fatigue at the connection point and effectively extend the service life of the cable
·Built in calibration room for easy air calibration; The calibration room can also serve as a probe storage room at the same time
·Extra large LCD display screen with background lighting function, allowing clear reading even in dim environments
·Full battery operation, with a working life of up to 100 hours (alkaline battery); There is also a low battery display
| YSI 55 System Specifications | |||
| technical indicators | |||
| parameter | measurement range | resolution | Accuracy* |
| dissolved oxygen | 0 to 200% air saturation | 0.10% air saturation | ± 2% air saturation* |
| 0 to 20 milligrams per liter | 0.01 milligrams per liter | ± 0.3 milligrams per liter* | |
| temperature | -5 ℃ to+45 ℃ | 0.1℃ | ±0.4℃* |
| salinity compensation | 0 to 40ppt | ||
| height compensation | 0 to 3000 meters | ||
| size | 24.1 cm (height) x 8.9 cm (width) x 5.0 cm (thickness) | ||
| weight | 0.73 kilograms | ||
| *The instrument specifications include the total error of the instrument and probe | |||
| Buying Guide | |
| instrument | |
| 55-12 | 55 type dissolved oxygen and temperature measuring instrument, 3.7-meter cable |
| 55-25 | 55 type dissolved oxygen and temperature measuring instrument, 7.5-meter cable |
| 55-50 | 55 type dissolved oxygen and temperature measuring instrument, 15 meter cable |
| 55D discontinued | 55D dissolved oxygen and temperature measuring instrument (without probe) |
| D-type probe | |
| 55D-12 discontinued | Detachable dissolved oxygen/temperature probe, 3.7-meter cable |
| 55D-25 discontinued | Detachable dissolved oxygen/temperature probe, 7.5-meter cable |
| 55D-50 discontinued | Detachable dissolved oxygen/temperature probe, 15 meter cable |
| accessories | |
| 5050 | Carrying case, hardware |
| 5520 | Plastic portable case (capable of accommodating 7.5-meter cables) |
| thin film | |
| 5685 | Semi sensitive membrane (30 pieces, with) |
| 5775 | Standard film (30 pieces, with |
| 5576 | High sensitivity membrane (30 pieces, with) |
| 5793 | Standard film (150 pieces) |
| 5794 | High sensitivity membrane (150 pieces) |
| Note: Standard film is suitable for the vast majority of situations. High sensitivity membranes can be used at low temperatures or low dissolved oxygen levels; On the contrary, when the dissolved oxygen level is very high or requires slightly longer monitoring, a semi sensitive membrane can be used. | |