Welcome Customer !

Membership

Help

Shenzhen Ruitaier Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shenzhen Ruitaier Technology Co., Ltd

  • E-mail

    13714836101@163.com

  • Phone

    13714836101

  • Address

    Building B, No. 3 Third Road, Yangyong Industrial Zone, Songgang Street, Bao'an District, Shenzhen

Contact Now

8-channel electronic cigarette life testing machine

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
1、 8-channel electronic cigarette life testing machine product introduction: This machine is used to test electronic cigarette sets and e-liquids. It adopts a cylinder piston suction method and determines whether the electronic cigarette set is qualified by setting the corresponding smoking duration, smoking volume, and smoking frequency. It is suitable for large and small power electronic cigarette sets
Product Details

1、 8-channel electronic cigarette life testing machine product introduction:

This machine is used for testingElectronic cigarette holderAnd e-liquid, using cylinder piston suction, determined by setting the corresponding smoking duration, smoking volume, and smoking frequencyElectric cigarettesWhether it is qualified and suitable for large and small powerElectric cigarettes.

2、 Specification parameters of 8-channel electronic cigarette life testing machine

station

8station

Aspiration

Cylinder piston type (using 8 cylinders)

Smoking volume

150ML

(The supplier shall ensure that the set volume and actual consistency error do not exceed 1ml

Suction resistance control

Automatic control of upper and lower limits of suction resistance, automatic alarm for exceeding the upper limit and falling below the lower limit

duration

1-9.9 Seconds(The supplier shall ensure that the corresponding set parameter values are achieved under a single port volume of 50-150ml

Interval between each mouth

1-999 Seconds

Number of smoking ports

1-999s

power

Stepper motor (6N/M)+PLC

Cylinder push-pull mechanism

ball screw

Touch screen counter

The number of times can be set, and it will automatically stop when the set number of times is reached

Special Features

Smoke free automatic stop operation and alarm prompt

Special Features

The following process can be set up at once: (automatic volume control)

For example, set 60ml per sip for 3 seconds with a 5-second interval between each sip, for a total of 300 puffs, with a 10 minute interval between every 50 puffs.

Display and control mode

Touch screen+PLC+self written program

power supply

1♪, ♪ AC220V

  1. Detailed configuration of 8-channel electronic atomizer lifespan testing machine:

    1. Framework: Cold rolled steel plate double-sided baking paint treatment is adopted, with a steel plate thickness of ≥ 1.5mm. A fully transparent window is used at the suction cylinder for easy observation by operators, with a transparent window thickness of ≥ 3mm. The front and back of the equipment are all equipped with movable doors and snap locks, and the movable door design is reasonable, making it easy for operators to quickly remove and clean parts on a regular basis;

    2. Suction cylinder: It adopts a fully transparent and graduated cylinder with a wall thickness of ≥ 4.0mm and a cylinder scale accuracy of 1mm. The suction cylinder is made of high wear-resistant and high-strength materials to ensure that it does not wear, scratch, deform, or crack. The fixed seat of the suction tube is easy to disassemble and the sealing ring design is reasonable, resistant to smoke and oil corrosion, and there will be no gas infiltration or leakage;

    3. Suction piston: The suction piston has good sealing and small deformation, does not scratch the suction cylinder, and does not leak air. The piston rod adoptsFood grade stainless steel SUS304Not rusting or deforming;

    4. Screw fixing seat and connecting parts: Made of 45 # steel chrome plated orFood grade stainless steel SUS304Steel plate thickness ≥ 10mm;

    5. Control circuit: The control circuit is separated from the suction pipeline, and it is necessary to avoid the leakage of the pipeline during disassembly and assembly, which may affect the circuit and ensure safety;

    6. Pipeline: The suction cylinder pipeline is arranged at the top, the suction product pipeline is arranged in the middle, and the exhaust pipeline is arranged at the bottom. All pipelines have no horizontal layout to prevent oil accumulation in the pipelines;

    7. Exhaust gas collection device: The equipment is designed with an exhaust gas collection device that uses water cooling for collection;

8通道电子烟具寿命试验机