AC power comprehensive analyzer electric motor economic operation instrument; Model: DP-S1006 $r $n $r $n DP-S1006 is an AC power comprehensive analyzer that combines microcontroller technology with TFT color screen display to provide users with a convenient operating platform. It can measure three-phase voltage, current, power, power factor, cumulative electricity, and also perform harmonic analysis. Built in printer that can print measurement data at any time, making it convenient for users to save measurement data in real time. There are two measurement methods available: three item three line and three item four line.
AC power comprehensive analyzer Electric motor economic operation instrument Model: DP-S1006
DP-S1006 is an AC power comprehensive analyzer that combines microcontroller technology with TFT color screen display to provide users with a convenient operating platform. It can measure three-phase voltage, current, power, power factor, cumulative electricity, and also perform harmonic analysis. Built in printer that can print measurement data at any time, making it convenient for users to save measurement data in real time. There are two measurement methods available: three item three line and three item four line.
AC power comprehensive analyzer Electric motor economic operation instrumentMain performance indicators
1. Basic testing items
Three phase AC voltage Ua, Ub, Uc and voltage mean U
Three phase AC currents la, lb, lc and average current l
Power grid frequency F
Active power Pa, Pb, Pc and three-phase total active power P
Reactive power Qa, Qb, Qc and three-phase total reactive power 0
The apparent power Sa, Sb, Sc and the total apparent power S of the three phases
Power factors cos φ 1, cos φ 2, cos φ 3, cos φ 4 (cos φ 4 is the average power factor of the three phases)
Real time display of voltage and current waveforms for each phase and amplification of single-phase.
Real time display of vector graphics, analysis of phase values and phase differences.
Cumulative power consumption measurement (cumulative time interval unit in minutes, cumulative total time unit in minutes)
Harmonic analysis: Measure the fundamental frequency, waveform distortion rate, and various harmonic levels (20th harmonic) of the Ua phase voltage.
Print data: Built in printer that can print measurement data at any time.
L can display and set the current time.
8-inch color touch screen display
Calculate 11 parameters for the economic operation of electric motors and analyze their operating conditions
Calculate 7 parameters of electric motor operation and measure cumulative power consumption
Automatically calculate the capacitance for on-site compensation and the annual energy savings after compensation
2. Economic operation test items for electric motors
The instrument database stores YE2、YE3、YX2、Y、YR、J、J2、JR、JR2、JS、JS1、JS2、YX、YPZC、FX、FGX2、FO、JF03 Waiting for over 80 series and nearly 10000 motor parameters: model, rated power, rated voltage, rated current, rated efficiency, no-load current, no-load power, power factor. If there is no corresponding motor model in the database, it can be easily added, modified, and operated through the database module. (You can add and modify the motor models in the database and save them)
Economic operation test items for electric motors: input voltage, input current, power factor, input power, reactive power economic equivalent, load factor, and comprehensive efficiency.
Calculation of motor operating parameters: comprehensive power consumption, allowable comprehensive efficiency, and rated comprehensive efficiency.
Analysis of the operating condition of the tested motor: In the economic and non economic operating zones, the capacitance for on-site compensation and the annual energy savings after compensation are automatically calculated.
If the tested motor operates in a non economic operating area, calculate the on-site compensation capacitance and the annual energy savings A after compensation (calculated based on an annual operating time of 3600 hours).
3. Range of measurement
Voltage: 0-420V (phase) 50-750V (line) (range can be expanded with PT)
Current: 0.5-600A (range can be expanded with CT)
Frequency: 50 ± 10%
Visual power: 0.025-750kVA
Active power: 0-750kW
Reactive power: 0-750kVar
Power factor: 0-1.0
Load rate: 0-120%
Efficiency: 0-100
Active electrical energy: 0 to any value
Input power: 0-750kW
4. Measurement accuracy
Voltage level 0.5 ± (0.5% of nominal value+0.001% of range) ± 1 word;
Current level 0.5 ± (0.5% of nominal value+0.001% of range) ± 1 word;
Power level 1.0 ± (1.0% of nominal value+0.001% of range) ± 1 word;
Absolute error of power factor<0.005
Frequency error<0.1Hz
Comprehensive accuracy: 1.0 level ± (1.0% of nominal value+0.001% of range) ± 1 word
5. Usage conditions
Environmental temperature 0-40 ℃
Relative temperature ≤ 85%
There are no large amounts of corrosive gases around
Working power supply: internal (voltage test line) 380V 50 Hz ± 10%
External (voltage test line) 220V 50 Hz ± 10%
to configure:
One AC power comprehensive analyzer, three clamp type current transformers, one voltage testing wire, one power cord, one roll of printing paper, one user manual, and one motor manual.