Three channel wireless ultraviolet radiometer; Model: DP-XM10 $r $n 160; The $r $nDP-XM10 wireless UV radiometer adopts SMT surface mount technology, uses digital chips, and has a streamlined design for the instrument housing. The detector has been calibrated for spectral and angular characteristics, and its performance is stable. This instrument is suitable for UV irradiance measurement work in sterilization, water treatment, breeding, photochemistry, polymer material aging, flaw detection, UV light source, plant cultivation, integrated circuits, photolithography, etc.
Three channel wireless ultraviolet radiometer Model: DP-XM10
The DP-XM10 wireless UV radiometer adopts SMT surface mount technology, uses digital chips, and has a streamlined design for the instrument housing. The detector has been calibrated for spectral and angular characteristics, and its performance is stable. This instrument is suitable for UV irradiance measurement in sterilization, water treatment, breeding, photochemistry, polymer material aging, flaw detection, UV light source, plant cultivation, integrated circuits, photolithography, and other fields.
The measurement performance of DP-XM10 wireless ultraviolet radiation meter complies with the standard of "JJG879-2015 Verification Regulations for Ultraviolet Radiation Illuminometer Measurement".
Three channel wireless ultraviolet radiometerspecial point
*Spectral and angular characteristics have been rigorously calibrated
*Host IPS LCD display
*Wireless detector, remote non exposure measurement
*Automatic range
*Lithium battery
*Real time display of battery level
Main technical indicators
*The probe model, wavelength range, and peak wavelength are as follows:
(1) WUV254 probe: λ: (230-275) nm; λP=254nm
(2) WUV297 probe: λ: (275-330) nm; λP=297nm
(3) WUV313 probe: λ: (290-340) nm; λP=313nm
(4) WUV340 probe: λ: (315-370) nm; λP=340nm
(5) WUV365 probe: λ: (320-400) nm; λP=365nm
(6) WUV420 probe: λ: (375-475) nm; λP=420nm
Select according to the wavelength range that needs to be measured 3 probes
*Range of irradiance measurement:
(0.1-200000) mW/cm2 * Relative indication error: ± 8%
*Cosine characteristic (directional response) error: 10%
*Linear error: ± 1.5%
*Shift error: ± 1%
*Short term instability: ± 1% (after 30 minutes of startup)
*Fatigue error: 3%
*Zero value error (full-scale FS): ± 1%
*Response time: 1 second
*Usage environment: Temperature (0-40) ℃, humidity<85% RH
*Size and weight:
Lord 机: 103mm×76mm×43mm; 0.15kg
Single probe:f62mm×52mm; 0.23kg
*Power supply: Built in rechargeable lithium battery, equipped with charger