E-mail
root@apsmyx.com
-
Phone
18001312670,17600971176
-
Address
Room 821, No. 102 Chaoyang North Road, Chaoyang District, Beijing (100123)
Beijing Meiya Xian Technology Co., Ltd
root@apsmyx.com
18001312670,17600971176
Room 821, No. 102 Chaoyang North Road, Chaoyang District, Beijing (100123)
AH2550A measures capacitance and losses in the medium to high impedance range, allowing for the use of 3 terminals instead of 5 to connect the tested device. Its unparalleled precision lies in the design and production of a 40 year capacitor bridge. That is, the result of uniquely designed transformer ratios. Equally important, the unique temperature control and standard fused silicon capacitors give it high measurement stability and immunity to mechanical shocks. These elements form a true 1kHz independent and precise test capacitance loss
The capacitive bridge that consumes the result.
Key Metrics
1) Accuracy: 5ppm.
2) Stability: less than 1ppm/year.
3) Resolution: 0.8aF, error 0.15ppm.
4) Temperature coefficient: 0.03ppm/℃.
5) Measurement of extremely low loss: loss factor less than 1.5 × 10-8 tan δ, conductivity less than 3 × 10-7 Siemens, or
Greater than 1.7 × 106 euros.
6) 3 terminal coaxial cable connector connection points to minimize joint costs and cable count.
7) Swap polarity method (signal reversal) to minimize the influence of external power lines or other surrounding signals.
8) Automatic testing.
9) IEEE-488 and IEEE-1174 interfaces allow remote devices to function as controllers or recorders.
10) Programmable functionality that does not require an external controller.
11) Complete or brief English instructions or error messages.
12) Large and variable brightness display, with 8 digits used to display capacitance and losses.
13) Measurement of capacitance deviation, loss, or both simultaneously.
14) Zero calibration test fixture for capacitance and loss.
15) External ± 100V DC bias voltage.
16) External triggering capability.
17) Automatic internal calibration.
18) NIST traceability.
19) Self detection and diagnosis can be performed under external signals.
20) 3-year warranty.
21) Better noise suppression curve.
22) Differential mode: allows testing of small and rapidly changing settings compared to fixed capacitor/loss designs, in order to
The values of capacitance and loss are quickly displayed in the form of voltage.
Application example of AH2550A
Transmission of Level 1 or Level 2 Metrology Standards
Calibration of Fuel Sensor 2
3 Ultra low temperature tests
Measurement of thermal expansion coefficient of any material, especially metals, including non metals
Radiation measurement and reduction of non-metallic changes in 5-crystal structures
6. Fast, accurate, and direct humidity measurement
Measurement of thickness of 7 metals or dielectrics
Precise measurement of concentration of liquids and vapors
9 AC resistance measurement
10 ultra small displacement, deformation or strain measurements (very small, less than one millionth of visible light wavelength)
11 Quality determination and characteristic testing of any substance (solid, liquid, gas). The existing polluted water is particularly susceptible to
Detected. For details, please refer to ASTMD150 and D924.
Measurement of pollutants in refrigerants
13. Monitor chemical reactions
14 applications involve measuring small changes in capacitance and inductance. AH2500A is very good at these, it has a very high resolution
And stability
15 research, development, and production testing of capacitance or loss sensors
Replacing capacitive sensors with 16 to achieve ultra-high sensitivity measurement
17 pressure measurement, ranging from high vacuum to high pressure
18 very high pressure gauges use solid dielectric capacitors (patent number 3787764)