E-mail
sales@grantlab.com.cn
-
Phone
18510859188
-
Address
1011, Building A, East Asia Wangjing Center, Guangshun South Street, Chaoyang District, Beijing
Beijing Funo Technology Development Co., Ltd
sales@grantlab.com.cn
18510859188
1011, Building A, East Asia Wangjing Center, Guangshun South Street, Chaoyang District, Beijing
new-typeAtmosSeries Anti Chemical Corrosion Fixed Optical Path Gas Pool
For current applications such as electronic gas, mixed gas, and ambient gasSpecacLaunched a new modelAtmosThe advantage of a gas pool with a fixed optical path is that it does not require the use of laser collimation or complex variable optical path adjustment. High flux and rapid measurement can be carried out for a certain range of concentration gases.
The Atmos gas pool adopts the White pool design principle, which optimizes the volume, reduces the intake volume, and improves the luminous flux compared to the original gas pool, making it more corrosion-resistant.
Fixed optical path length from2.5Mi to20rice
Metal shell with nickel plating coating
volume≈0.5L for 5m and ≈0.2L for
2.5m, ≈2L for 10m, < 5 L for 20moptionalK
Type perfluororubber sealing ring is designed for strengthening corrosive gasesHigher pressure
(metal body) : 120psi真空度-4: 10torr
Need to configure a vacuum pump to achieve
CaF2, ZnSe window options available
Stainless steel material gold mirror
No bracket design1
design improvement
As can be seen from the above pictureAtmos gas pool abandons the originalT
The mirror design eliminates the mirror frame and completely avoids corrosion problems. The circular total reflection design allows all light to be reflected internally without loss, greatly increasing the luminous flux and significantly improving weak signals, resulting in an increased detection limit.2
design improvementCoating:The original and other manufacturers' mirror materials are aluminum,Atmos
Adopting a stainless steel mirror design to prevent the peeling of the mirror bottom material caused by corrosion, resulting in the detachment of gold plating.
The internal energy of the nickel plated passivation coating can almost resist most corrosive gases.3
design improvement
Adjustable luminous flux
Many pool designs have fixed mirrors, which can be used for collimation without the need for a base plate and may not allow for flexible adjustment of light flux in certain situations.
Atmos adopts a non fixed reflector design that can be adjusted to a maximum light flux, which is very useful for impurity testing in pure gas.
Can be adjusted by adjusting the reflector and internal hexagonal screw
Can adjust the center of the outgoing and incoming light accurately
Can achieve optimal energy levels4
design improvementAtmos
Gas pool performanceDue to optimization of the concave surface of the top reflector3D6000Numerical simulation and practical application
Secondary reflex experiment. The original luminous flux and reflection frequency have been adjusted.5
design improvement
Sealing design
A new sealing design has been developed for toxic and flammable gases, making it particularly suitable for measuring special and corrosive gases
Protective gas can be introduced into the optical reflection boxThe window panel adopts a double-layer sealing design,VType orK
The design of the sealing ring is optional,Window panelPTFE4Double layer reinforced anti-corrosion gasket, using threaded ring integral seal, evenly compressed, will not be used like traditional gas pools
Tighten one or more screws to prevent uneven compression and leakage of the window panel, as well as to prevent uneven compression and breakage of the window panel.
Using a ring shaped disassembly tool for easy and quick replacement*High and normal pressure can reach
150Psi
The connection between the upper and lower chambers also adopts a double sealing ring designoptionalVorK
Type sealing ring, especially suitable for special application gases such as corrosion
By connecting the corrugated tube, the overall optical air path can be isolated6
design improvement
Interface connection
Flexible and versatile connection designadopt1/4
Design of inch standard stainless steel pipelineCan be connected to an adapter on the pipelineVCR
Vacuum sealed connection
Flexible external connection of needle valves, pressure gauges, flow meters, etc
It can be heated through a heating sleeve or insulated pipeline
Heating or insulation of the overall gas environment
Can be connected to a vacuum pump or replaced by positive pressure blowing into the body7
design improvement
Alignment and
wash
The customer is concerned about issues such as corrosion, atomization, adsorption, cleaning, and storage after use
Cleaning is very convenient for the use of corrosive gases or special gases
Directly disassemble and rinse the mirror surface with distilled water and neutral detergent
Double sided mirrors are easy to disassemble
Window panels can also be cleaned separately8
Laser collimators can also be configured for the alignment of pipelines and mirrorsdesign improvement
Atmos
Gas pool heating system
No more tedious installation of heating sleeves or occupying instrument space
The heating sleeve is designed with a quick snap fastener, which can be installed and locked in one second
Heating and insulation directly wrapped
New lock buckle adapter, no shakingSuitable for various types of gas poolsFor
10m 20m