Welcome Customer !

Membership

Help

Shenzhen Huachenkang Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shenzhen Huachenkang Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 43 Changfa West Road, Bantian, Longgang District, Shenzhen

Contact Now

Armored Thermocouples, Flexible Thermocouples, Pressure resistant Industrial Thermocouples

NegotiableUpdate on 09/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Armored thermocouples are usually used in conjunction with display instruments, recording instruments, electronic computers, and other devices. Armored thermocouples directly measure the surface temperature of liquids, vapors, gases, and solids within the range of 0 ° C to 1300 ° C in various production processes.

Product Details

Product Introduction

sheath thermocoupleUsually used in conjunction with display instruments, recording instruments, electronic computers, etc.sheath thermocoupleDirectly measure the surface temperature of liquids, vapors, gases, and solids within the range of 0 ° C to 1300 ° C in various production processes.
sheath thermocouplefeature
Less thermal response time, reducing dynamic errors;
Flexible installation and use;
Large measurement range;
High mechanical strength and good pressure resistance;
sheath thermocoupleworking principle
The electrode is composed of two different conductor materials. When there is a temperature difference between the measuring end and the reference end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.
sheath thermocoupleMain technical parameters
Product execution standards
IEC584
IEC1515
GB/T16839-1997
JB/T5582-91
sheath thermocoupleMeasurement range and tolerance

model

graduation mark
Tolerance level
I
II
Allowable deviation
Measuring range°C
Allowable deviation
Measuring range°C
WRNK
K
±1.5°C
-40~+375
±2.5°C
-40~+333
±0.004ltl
375~1000
±0.0075ltl
333~1200
WRMK
N
±1.5°C
-40~+375
±2.5°C
-40~+333
±0.004ltl
375~1000
±0.0075ltl
333~1200
WREK
E
±1.5°C
-40~+375
±1.5°C
-40~+333
±0.004ltl
375~800
±0.004ltl
333~900
WRFK
J
±1.5°C
-40~+375
±1.5°C
-40~+333
±0.004ltl
375~750
±0.004ltl
333~750
WRCK
T
±1.5°C
-40~+125
±1°C
-40~+133
±0.004ltl
125~350
±0.0075ltl
133~1000
WRPK
S
±1°C
0~+1100
±2.5°C
0~600
±[0.003(t-1100)]
1100~1600
±0.0025ltl
600~1600

Room temperature insulation resistance
sheath thermocoupleAt an ambient temperature of 20 ± 15 ° C and a relative humidity of no more than 80%, the test voltage is 500 ± 50V (DC), and the insulation resistance between the electrode and the outer sleeve is greater than 1000M Ω. That is, the insulation resistance of a 1m long sample is 1000M Ω; the insulation resistance of a 10m long sample is 100M Ω;
Wire diameter and material

Even silk form

Single branch type
Double branch type
Casing diameter
F2F3 F4 F5 F6 F8
F3F4 F5 F6 F8
Material of casing
E﹑J﹑T
1Cr18Ni9Ti
1Cr18Ni9Ti
K﹑N
1Cr18Ni9Ti GH3030
1Cr18Ni9Ti GH3030
S
GH3039
GH3039

sheath thermocoupleInstallation fixed form

sheath thermocoupleForm of junction box

sheath thermocoupleRecommended temperature for use

Variety

Sleeve Material
Outer diameter
Usage temperature(°C)
long-term use
short-term use
nickel-chromium-Nickel silicon
1Cr18Ni9Ti
2.0
600
700
3.0,4.0,5.0,6.0,8.0
800
900
GH3030
2.0,3.0
800
900
4.0,5.0
900
1000
6.0,8.0
1000
1100
Nickel chromium silicon-Nickel silicon
1Cr18Ni9Ti
2.0
600
700
3.0,4.0,5.0,6.0,8.0
800
900
GH3030
2.0,3.0
900
1000
4.0,5.0
1000
1100
6.0,8.0
1100
1200
GH3039
2.0,3.0,4.0
1000
1100
5.0,6.0,8.0
1100
1200
nickel-chromium-Copper nickel
1Cr18Ni9Ti
2.0
500
600
3.0,4.0,5.0
600
700
6.0,8.0
700
800
iron-Copper nickel
1Cr18Ni9Ti
2.0
400
500
3.0,4.0,5.0
500
600
6.0,8.0
600
750
copper-Copper nickel
1Cr18Ni9Ti
2.0,3.0,4.0,5.0
250
300
6.0,8.0
300
350
platinum-rhodium10 Platinum
GH3039
2.0,3.0,4.0
1000
1100
5.0,6.0,8.0
1100
1200

sheath thermocoupleModel naming method

model

Instructions
W

Temperature Instrument

R

thermocouple

P
Temperature sensing element material
P Platinum Rhodium10 Platinum

M
Nickel chromium silicon- Nickel silicon

N
nickel-chromium- Nickel silicon

E
nickel-chromiumCopper nickel

C
copperCopper nickel

F
ironCopper nickel

K

Armored type

none
Even number of threads
single piece

2
Double branch

1
install
fixed
form
No fixed device

2
Fixed card sleeve thread

3
Activity card sleeve thread

4
Fixed card sleeve flange

5
Activity card sleeve flange

2
Form of junction box
Anti spray type

3
waterproof type

6
Circular plug-in type

7
Flat plug-in type

8
Handle type

9
Compensation wire type

1
Workplace format
Insulated type
4
M
Additional equipment
Form setting
Contact block type

G
Hoop type

Armored thermocouple WZPK2-236G model example