- Phone
-
Address
No. 43 Changfa West Road, Bantian, Longgang District, Shenzhen
Shenzhen Huachenkang Technology Co., Ltd
No. 43 Changfa West Road, Bantian, Longgang District, Shenzhen
Replace Pentronic Swedish temperature sensor, German Jumo JUMO temperature probe, domestic probe
PT100Platinum thermistor temperature probe, temperature sensor
PT100 for disinfection cabinet, high-precision PT100 temperature sensor, stable and consistent PT100 temperature sensor, PT100 for medical equipment, PT100 for sterilization box, customized production PT100
working principleIntroduction:
The PT100 platinum resistance element, as a temperature sensor, works by changing the resistance value of the platinum resistance wire with temperature under the action of temperature. The relationship between temperature and resistance is close to a linear relationship, with minimal deviation that can be ignored over time, and stable electrical performance.
Dual core straight probe,8Wire system, high precision,AGrade.
1. Thermal resistance core: 2 * Pt100 8-wire type
2. Probe appearance: straight head
3. Temperature measurement range: -50 ℃+200 ℃
4. Probe size: φ 4 × 150 ± 1mm
5. Sealing: using silicone sealing; Protective sleeve: Stainless steel SUS304, optional SUS316
6. Working current ≤ 5mA. The resulting temperature rise ≤ 0.3 ℃
7. Thermal response time t0.2 (s)
8. The temperature of platinum resistance is0℃timeofelectricityblockvalueR0=100±0.06Ω
9. The maximum deviation at 0 ℃ is 0.15 ℃; The maximum deviation at 100 ℃ is 0.35 ℃; The maximum deviation inside the steam chamber at 120 ℃ is 0.39 ℃
10. The length of the wire is 8 meters ± 0.02 meters
【 PT100 for Disinfection Cabinets _ High Precision PT100 Temperature Sensor _ Stable and Consistent PT100 Temperature Sensor _ PT100 for Medical Equipment _ PT100 for Sterilization Boxes _ Customized Production PT100 】
Dual core curved probe,8Wire system, high precision,AGrade.
1. Thermal resistance core: 2 * Pt100 8-wire type
2. Probe shape: elbow
3. Temperature measurement range: -50 ℃+200 ℃
4. Probe size: φ 4 × 150mm
5. Sealing: using silicone sealing; Protective sleeve: stainless steel SUS304, optional SUS316.6., working current ≤ 5mA. The resulting temperature rise ≤ 0.3 ℃
7. Thermal response time t0.2 (s)
8. The maximum deviation at 0 ℃ is 0.15 ℃; The maximum deviation at 100 ℃ is 0.35 ℃; The maximum deviation inside the steam chamber at 120 ℃ is 0.39 ℃
9. The temperature of platinum resistance is0℃The resistance value at time R0=100 ± 0.06 Ω
10. Wire length 8 meters ± 0.02 meters
Single core straight probe,4Wire system, high precision,AGrade.
1. Thermal resistance core: Pt100 4-wire type
2. Probe appearance: straight head
3. Temperature measurement range: -50 ℃+200 ℃
4. Probe size: φ 4 × 150mm
5. Sealing: using silicone sealing; Protective sleeve: Stainless steel SUS304, optional SUS316
6. Working current ≤ 5mA. The resulting temperature rise ≤ 0.3 ℃
7. Thermal response time t0.5 (s)
8. The maximum deviation at 0 ℃ is 0.15 ℃; The maximum deviation at 100 ℃ is 0.35 ℃; The maximum deviation inside the steam chamber at 120 ℃ is 0.39 ℃
9. The temperature of platinum resistance is0℃The resistance value at time R0=100 ± 0.06 Ω
10. The length of the wire is 8 meters ± 0.02 meters
【PT100 for disinfection cabinet, high-precision PT100 temperature sensor, stable and consistent PT100 temperature sensor, PT100 for medical equipment, PT100 for sterilization box, customized production PT100
Single core curved probe,4Wire system, high precision,AGrade.
1. Thermal resistance core: Pt100 4-wire type
2. Probe shape: elbow
3. Temperature measurement range: -50 ℃+200 ℃
4. Probe size: φ 4 × 150mm
5. Sealing: using silicone sealing; Protective sleeve: Stainless steel SUS304, optional SUS316
6. Working current ≤ 5mA
7. Thermal response time t0.5 (s)
8. The maximum deviation at 0 ℃ is 0.15 ℃; The maximum deviation at 100 ℃ is 0.35 ℃; The maximum deviation inside the steam chamber at 120 ℃ is 0.39 ℃
9. The temperature of platinum resistance is0℃The resistance value at time R0=100 ± 0.06 Ω
10. Wire length 8 meters ± 0.02mm
【PT100 for disinfection cabinet, high-precision PT100 temperature sensor, stable and consistent PT100 temperature sensor, PT100 for medical equipment, PT100 for sterilization box, customized production PT100
This product uses imported PT100 armored platinum resistance temperature sensing elements, filled with imported thermal conductive resin, sealed with silicone, and protected with stainless steel SUS304 sleeve. PVC, silicone, PTFE, and fiberglass insulation materials with metal mesh are used to connect cables, ensuring the sealing and long-term reliability of the product. It has the characteristics of fast reaction speed, short thermal response time, high temperature resistance, stable performance, and high accuracy,majorSuitable for temperature detection in sterilization cabinets, strictly followingIEC-60751standard
To meet customers' bulk orders, ensure supply, and offer competitive prices,Completely replaceable for similar imported products.
Application scenarios: PT100 platinum resistance temperature probe, PT100 temperature sensor, used to measure the temperature of gases or liquids, mainly used in medical steam sterilization cabinets, water bath sterilization cabinets, high-pressure sterilization cabinets, wet heat sterilization cabinets HVAC、 Refrigeration and heating devices, ovens, laboratories, food factories, breweries
【PT100 for disinfection cabinet, high-precision PT100 temperature sensor, stable and consistent PT100 temperature sensor, PT100 for medical equipment, PT100 for sterilization box, customized production PT100