BDR-7BD1-7 DBQ-S JXW-25A FB-1 switch representation transformerSouth Railway Signal

BD1-7 switch indicates transformerStructure and characteristics:
Using the AX type relay plug-in structure, the BD1-A7 switch representation transformer is combined with the resistor RXJC-10W, capacitor CTA-4uf-400V.AC, and outer cover to form a structure
The DBD-A7 turnout representation unit has the advantages of easy installation, small size, low noise, and beautiful appearance.
BD1-7 switch indicates transformerProduct appearance and installation:
Use AX type relay socket connection. Dimensions: 165mm × 165mm × 6mm
Identify the hole numbers as 11 and 31.
Main technical specifications: Transformer capacity 34VA, input voltage 50Hz, 180V, 220V, output voltage 50Hz, 13V, 14V, 16V, primary no-load current 10mA, output current 2.08A.
Main features of the product:
1. The relay is a heavy-duty DC electromagnetic relay, which uses the principle of "constant gravity" to force the closing contact to disconnect when the coil is powered off.
2. Using silver silver cadmium oxide contacts, it has strong anti adhesion and low contact resistance.
3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stopper is installed at the closure between the armature and the iron core to ensure a small air gap in the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure the reliable dropping of the relay.
4. The front coil of the relay is a short-circuit coil enclosed by a diode, without a rectifier unit. The AC power supply is directly connected to the coil and has a certain lightning protection function.
5. The relay contact system consists of ordinary contacts, with four sets of common contacts for dynamic connection and dynamic disconnection conversion.
6. Relays should be used in conjunction with isolation transformers to adjust the system current to ensure reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.
Product dimensions:
Relay: 165 mm x 49 mm x 163 mm (length x width x height)
Socket: 157 mm x 48 mm x 22 mm (length x width x height)

BDR-7BD1-7 DBQ-S JXW-25A FB-1 switch representation transformerSouth Railway Signal
working environment
1. Working voltage: 24V ± 15% (ripple ≤ 50mV) Current ≤ 100mA
2. Working environment: Temperature: -25 ℃~+60 ℃
Humidity: ≤ 90% (25 ℃)
Air pressure: 70-106kpa
3. Track input: 12.5V ≤ IN ≤ 24V, * preferably 20V
4. Input impedance: 400 ± 20 Ω
5. Receiving phase: -90? ±20?
6. Local power supply: 110V/25Hz current ≤ 4mA
7. Power supply design suggestion: Based on the characteristics of the circuit breaker, redundancy must be considered in the design. It is recommended to design according to 1.6-2 times the rated current.
Main technical indicators
Mechanical characteristics of relays:
a) The contact gap shall not be less than 0.6mm.
b) The front contact pressure shall not be less than 150mn (15gf).
c) The pressure at the rear contact point shall not be less than 150mn (15gf).
Electrical characteristics of relays:
a) Rated current ac2.1a.
b) The working value is not greater than ac1.5a.
c) The release value shall not be less than ac0.35a.
d) The contact resistance of the relay should not exceed 0.05 Ω when passing a current of 100ma.
e) Under the standard atmospheric conditions of the experiment, its insulation resistance should not be less than 100m Ω;
f) The insulation withstand voltage of the relay should be able to withstand AC sine wave voltage of 50Hz and 1000V effective value voltage under the condition of air pressure not less than 86kPa (equivalent to altitude below 1000m), and there should be no breakdown or flashover phenomenon after 1 minute. The voltage value during repeated testing should be 75% of the original test voltage value.
Product installation method:
The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring.
Relay identification sales numbers 13 and 53.