ZFJ-H18-H62FB-1 JWXC-1700 WXJ-50 Lightning Protection Compensator Nantie Signal

FB-1 FB-2 lightning protection compensator is a product that compensates for 25Hz local power supply and protects track input. It is used in the 97 type 25Hz phase sensitive track circuit in the station

Main technical indicators:
1.Capacitor(CTA)Local pressure resistance25 0V;
2.Selenium heap(XT-1-22C5C)Receive working voltage90V.
ZFJ-H18-H62FB-1 JWXC-1700 WXJ-50 Lightning Protection Compensator Nantie Signal
ZG1R -40/0.5 silicon rectifierThe AX relay base is connected to the socket, and its external dimensions are 165mm × 48.5mm × 150mm,ZG2-42/0.5 silicon rectifierConvert AC to DC for the power supply equipment of the railway signal 42 volt DC power supply.
ZG2-42/0.5 silicon rectifierSpecifications:
Model Capacity (VA) Primary Coil Secondary Coil
Voltage (V) No load current (mA) Voltage (V) Full load current (A)
ZG2—42/0.5 13 220 10 50/80/130 0.1
ZG2-42/0.5 silicon rectifierUsage environment:
2.1 Surrounding air temperature: -40 ℃ -+60 ℃
2.2 Relative humidity of air: not exceeding 90% (temperature+25 ℃)
2.3 Atmospheric pressure: 74.8-106kPa (altitude equivalent to below 2500m)
2.4 Vibration frequency: 10-55Hz, acceleration of 2g
Main features of the product:
1. The relay is a heavy-duty DC electromagnetic relay, which uses the principle of "constant gravity" to force the closing contact to disconnect when the coil is powered off.
2. Using silver silver cadmium oxide contacts, it has strong anti adhesion and low contact resistance.
3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stopper is installed at the closure between the armature and the iron core to ensure a small air gap in the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure the reliable dropping of the relay.
4. The front coil of the relay is a short-circuit coil enclosed by a diode, without a rectifier unit. The AC power supply is directly connected to the coil and has a certain lightning protection function.
5. The relay contact system consists of ordinary contacts, with four sets of common contacts for dynamic connection and dynamic disconnection conversion.
6. Relays should be used in conjunction with isolation transformers to adjust the system current to ensure reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.
Product dimensions:
Relay: 165 mm x 49 mm x 163 mm (length x width x height)
Socket: 157 mm x 48 mm x 22 mm (length x width x height)
Product installation method:
The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring.
Relay identification sales numbers 13 and 53.