Beijing Times New Wei Portable Micro Dissolved Oxygen Analyzer

NegotiableUpdate on 10/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: Beijing Times New Wei Portable Trace Dissolved Oxygen Meter is a highly functional and easy-to-use high-precision ppb level dissolved oxygen meter. Chinese display and menu guidance make operation extremely convenient, with features such as multiple functions, high measurement accuracy, and easy portability. Measurement of trace dissolved oxygen in solutions from various industries.

Product Details

Details

The continuous measurement method for DO is the diaphragm electrode method. The diaphragm is composed of polytetrafluoroethylene fibers, polyethylene, etc., with platinum as the positive electrode and aluminum and lead as the negative electrodes. The two metal electrodes are immersed in an electrolyte solution, and the electrodes and electrolyte solution are housed in a small chamber of an aerobic semi permeable membrane. Connect the current measurement circuit, and molecular oxygen in the water diffuses through the membrane to the electrode surface, causing an electrode reaction. When the electrode parameters are constant, the stable diffusion current is proportional to the oxygen concentration in the water sample at a certain temperature.

Beijing Times New Wei Portable Micro Dissolved Oxygen Analyzer

The TP350 portable trace dissolved oxygen analyzer is a highly functional and easy-to-use high-precision microgram level dissolved oxygen analyzer. Chinese display and menu guidance make operation extremely convenient, with features such as multiple functions, high measurement accuracy, and easy portability. Can be used for measuring trace dissolved oxygen in solutions from various industries.

Beijing Times New Wei Portable Micro Dissolved Oxygen Analyzer

lHigh precision measuring electrode, imported membrane head with short response time, stable measurement, and high temperature resistance.

lAdopting advanced surface mount technology and integrated design, the high integration circuit design is stable and durable.

lAdvanced microcontroller technology, high performance, and low power consumption.

l24 bit A/D signal acquisition, high measurement accuracy, accuracy and reliability.

lChinese menu style operation, easy to understand, quick and convenient to operate.

lThe data loop storage function automatically clears overflow data, with simple operation and convenient query. It can store data for more than 10 years after power failure.

lLong continuous use time, up to 8 hours of measurement after fully charged.

lCompact and beautiful in appearance, easy to carry.

Protection level: IP65

Temperature sensor: Pt1000

Power supply: AC (85-265) V

Frequency (45-65) Hz

Power: ≤ 1W

Dimensions: 285mm × 60mm × 255mm

Weight: 2.28kg

Display: 128 × 64 LCD, Chinese display

Measurement range: (0.0-100) μ g/L, (100-1000)

μg/L、(1.00~20.00) mg/L(自

Dynamic switching)

Resolution: 0.1 μ g/L (0.0-100) μ g/L

1.0μg/L (100 ~1000)μg/L

0.01mg/L (1.00~20.00)mg/L

Repeatability: ≤ 1%

Accuracy: ± 1.0% FS

Response time: T90<5 minutes (25 ℃)

Temperature compensation range: (0-60.0) ℃

Water sample temperature: (5-45) ℃

Environmental temperature: (5-45) ℃

Environmental humidity: ≤ 90% RH (no condensation)

lAccessories Guide

lDissolved oxygen membrane head

lElectrode filling solution

lDissolved oxygen electrode

Precautions

1. The entire measurement system has a long response time, membrane rupture, and no oxygen medium

If the current in the medium increases, it is necessary to replace the membrane or electrolyte. each

Re polarization and calibration are required after membrane or electrolyte replacement.

2. Place the electrode into a flow cup, which can be obtained for on-site testing at any time

Quantity. The circulation cup allows water to flow from the bottom and water to flow from the top.

When measuring low oxygen, it is recommended to use a hard tube to connect the electrode flow cell,

To prevent oxygen from seeping into the waterway through the hose. Inlet water sample

Keep the flow rate as constant as possible.