The TP205 dew point meter uses gain regression, zero point automatic calibration, and the dew point sensor provided by VAISALA company, which constitutes the core measurement unit of the entire system. It condenses multiple new research achievements and technologies in dew point measurement, so that the dew point meter can accurately measure relative humidity and calculate the corresponding dew point even in low humidity or corrosive chemical gas molecules environments. The accuracy of the dew point meter is guaranteed to be within plus or minus 2 degrees when measuring dew points above negative 60 degrees.
lThe TP205 precision dew point meter is suitable for detecting moisture in dry gases, including H2, SF6, N2, O2, Ar2, CO2, compressed air, and other gases. It is widely used in industries such as power, chemical, aviation, metallurgy, medicine, and food.
lAdvanced probe protection function, anti pollution and anti-interference.
lThe automatic calibration program ensures the long-term stability of the instrument and overcomes almost all adverse factors in on-site measurements.
lReal time storage and printing of measurement data.
lUltra large true color touch screen.
l
l*The ultra large capacity storage function and digital power display.
lEasy to operate, convenient to carry, anti-interference, good repeatability, fast response speed, high sensitivity, and good stability.
lOptional RS232/485 signal output.
Storage temperature level: (-40~+70) ℃
Operating environment: Temperature: (5~+60) ℃
Humidity: (0-100)% RH
Pressure: (0-10) bar
Sample gas flow rate: No impact
Other configurations: Lithium battery, AC/DC dual-use, automatic switching,
Overcharge and over discharge protectionTP205 Precision Dew Point Meter: A New Dimension in the EraTP205 Precision Dew Point Meter: A New Dimension in the Era
Working voltage: AC/220V 50Hz
DC/11.1V lithium battery
Dimensions: 310mm × 290mm × 280mm
Weight: 4.6kg
Measurement range: (-100~0) ℃/(-60~+20) ℃ (depending on)
Selected sensors)
Dew point accuracy: ± 2 ℃
Response time: 63% [90%] 90s/450s
Resolution: Dew point 0.01 ℃
Repeatability: ± 0.2 ℃
Gas flow rate: SF6 is regulated at (0.5-0.9) L/min
Adjust H2 at (0.1-0.4) L/min
Pressure measurement: (0-1) MPa
Probe protection: Stainless steel sintered filter screen
lAccessories Guide
lSampling connection tube
ldetector
ldata cable
Precautions
1. It is prohibited to turn on or off the power supply of instruments in hazardous areas.
2. Charging is prohibited in hazardous areas.
During the measurement process, the flow regulating needle valve should be slowly opened to preventTP205 Precision Dew Point MeterTP205 Precision Dew Point Meter
Stop sudden changes in pressure to prevent damage to pressure and flow sensors.
During the use of the instrument, if the battery level indicator is insufficient, it should be promptly displayed
charge.
5. When connecting communication cables, do not operate with power on. The instrument and electricity must be connected