E-mail
2197115204@qq.com
-
Phone
13761613451
-
Address
No. 41, Lane 2688, Yindu Road, Minhang District, Shanghai
Shanghai Heyi Instrument Co., Ltd
2197115204@qq.com
13761613451
No. 41, Lane 2688, Yindu Road, Minhang District, Shanghai
1Product Introduction
Meet the measurement requirements for indoor radon concentration, pit radon concentration, water radon concentration, soil radon concentration, and radon release rate on building materials or soil surfaces, used for environmental impact assessment testing, geological and mineral tourism, construction development, scientific research institutes, and other units. PortableABSPlastic shell, anti drop, waterproof, suitable for field measurement use. External temperature and pressure sensor, accurately measuring the environmental conditions around the instrument; Equipped with Bluetooth function, configured with Bluetooth printer, and real-time printing of measurement results; The use of gas collection hood accessories can be used to measure the radon release rate on the surface of building materials or soil; By using soil gas collection rod accessories, radon concentration measurement in soil can be completed; By using glass bubble bottle accessories, the measurement of radon concentration in liquid samples can be completed.
2Technical indicators
1)Detector: Detachable cylindrical scintillation chamber detector;
2)Measurement objects: air radon, soil radon, water radon, surface radon release rate;
3)Measurement function: capable of detecting radon in air, soil, water, and surface4Fast point measurement function and continuous radon concentration measurement function;
4)Measurement range: Air radon:(2~50000000)Bq/m3;
5)Soil radon:(10~50000000)Bq/m3;
6)Radon in water:(0.01~50000)Bq/L;
7)Radon release rate:(0.001~200.000)Bq/[m2·s].
8)Measurement time: Air radon:25min(Point measurement);
9)Soil radon:10min(Point measurement);
10)Radon in water:25min(Point measurement);
11)Radon release rate:25min(Point measurement);
12)Continuous measurement:1~999minAdjustable (cycle).
13)Sensitivity:≥50 cpm/(Bq/L);
14)Background count rate:≤10cpm;
15)Repeatability:≤15%When the radon concentration is800Bq/m3Time);
16)Multi detector: The instrument host can be configured with multiple detectors, and the detectors can be replaced immediately for retesting at high radon concentration abnormal points;
17)Built in air pump: flow rate0.5、1.0The1.5L/minOptional, working hours and modes can be set;
18)Auxiliary measurement: temperature, air pressure, relative humidity;
19)Data interface: equipped withRJ45Ethernet port andUSBInterface;
20)Storage capacity:8GBMemory capacity, capable of storing10Measurement data over years old;
21)Alarm function: Radon concentration exceeding the threshold alarm prompt, the alarm threshold can be modified;
22)Instrument screen:5.6Inch color touch screen;
23)Power supply mode:8000mAhLithium ion rechargeable batteries220VCommunication adapter;
24)Environmental characteristics: Temperature-15℃~50℃Relative humidity≤98%rHNo condensation;
25)Remote software: equipped with a computerwebEnd software, which can remotely control instrument restart, timing, status monitoring, data query, download and analysis, work parameter modification and other functions;
26)Compliant with standards:GB/T16147-1995The scintillation bottle measurement method for radon concentration in the air,GB/T18883-2002Indoor air quality standards,GBZ/T155Method for determination of radon concentration in the air using scintillation flasks, etc;
27)Quick detection: automatic completion of instrument program“Background, sampling, measurement, calculation, radon emission”Wait for the steps and display the counting rate change curve of the detector during the radon removal process;
28)Continuous measurement: The instrument performs periodic measurements according to the parameters set by the user, and displays the radon concentration change curve during the continuous measurement process;
29)Detector switching: After replacing the detector, the corresponding detector number can be switched on the instrument software;
30)Self start upon startup: This function is activated to automatically perform continuous measurements after the instrument is turned on;
4Product Selection Table
Material Number |
Configuration Instructions |
YQ.2015.1.0006 |
Standard version, no other options available |