CE certified low-temperature power cable

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
CE certified low-temperature power cables are suitable for fixed installation in power distribution networks or industrial installations with rated voltage of 0.6/1kV and below.
Product Details

CE certified low-temperature power cableScope of application:Suitable for fixed installation in power distribution networks or industrial equipment with rated voltage of 0.6/1kV and below.

Usage characteristics

1. Power frequency rated voltage: U0/U (Um) 0.6/1 (1.2) kV. [1]

2. The maximum allowable long-term operating temperature for cable conductors is 120 ℃.

3. The maximum allowable temperature of the cable conductor during a short circuit (with a maximum duration of 5 seconds) shall not exceed 250 ℃.

4. The ambient temperature during cable laying should not be lower than 0 ℃.

5. The bending radius of the cable shall not be less than 15 times the outer diameter of the cable.

Applicable environment:-60 ℃~+45 ℃ (-20 ℃ to+120 ℃ optional)

Customs code: 854492100

Execution standards: EN50575:2014, EN13501-6, EN 60228, IEC 60502, GB12706, GB31247-2014

Cable operating conditions

Laying in the air

1. When a single core cable is laid in parallel, the center distance is twice the cable diameter for cables with a diameter of 185mm or less, and 90mm for cables with a diameter of 240mm or more.

2. Surrounding air temperature: 40 ℃

3. Long term maximum operating temperature of conductor: 90 ℃

4. Correction coefficient (k) for current carrying capacity at different environmental temperatures

Environmental air temperature

-60℃

-50℃

-40℃

-20℃

-10℃

0℃

10℃

20℃

30℃

40℃

Correction coefficient (k)

/

/

/

/

/

/

1.35

1.29

1.15

1.00

Direct burial

1. When a single core cable is laid without contact, the center distance of the cable is 2-2.5 times the diameter of the cable.

2. Soil temperature: 25 ℃

3. Long term maximum operating temperature of conductor: 90 ℃

4. Soil temperature coefficient: 1.0 ℃. m/w

5. Direct burial depth: 0.7m

6. Correction coefficient for download flow rate at different soil temperatures

soil temperature

20℃

25℃

30℃

35℃

40℃

Correction coefficient (k)

1.04

1.00

0.96

0.92

0.87

Installation and Usage

Selection of cables

1. The rated voltage U0/U (Um) of the cable is shown as follows: UO is the rated power frequency voltage between the conductors used in the cable design and the ground or metal shield, U is the rated power frequency voltage between the conductors used in the cable design, and Um is the maximum system voltage that the equipment can withstand.

2. Design and select the appropriate cable model and specifications based on the different laying environments and loads of the cables. Non armored type is suitable for overhead, indoor, tunnel, cable trench and other occasions, and cannot withstand mechanical external forces; Armored type can be directly buried underground under the same conditions as non armored type, and can withstand certain mechanical external forces. Single core cables are not allowed to be laid in pipelines that generate magnetism. Special types of cables should be selected for flammable, explosive, chemically corrosive, and high-temperature/low-temperature environments.

storage and transportation

During storage, cables should be packaged in a standardized manner to avoid long-term exposure to sunlight. Both ends should be reliably sealed, and long-term storage in damp environments is not allowed. The electrical panel should not be placed flat. When transporting, the height of the tray should be considered and effectively fixed. It is not allowed to lift several trays at the same time during lifting, and it is strictly prohibited to push them down from a high place.

Laying and installation

1. Special tools such as pay off racks and guide rollers should be used for cable laying to prevent mechanical damage and keep away from heat sources during the laying process.

2. When laying cables through conduits, the inner diameter of the conduit should not be less than 1.5 times the outer diameter of the cable. When multiple cables are threaded through conduits, twisting and squeezing of the cables is prohibited. The conduit should have sufficient capacity and the total area of the cables should not exceed 40% of the total area inside the conduit

3. The lowest temperature for cable laying shall not be lower than 0 ℃, and the bending radius shall not be less than 15 times.

4. When using the traction conductor clamp method for laying, the maximum allowable traction force is P=OA (N), A conductor cross-section O is 50N/mm (copper) and 30N/mm (aluminum).

Experiment:After installation, conduct insulation resistance test on the cable without load, and if necessary, perform AC power frequency withstand voltage test for 1 minute

CE certified low-temperature power cableFor more cable and distribution box products, please contact us! If you have any other questions, you can consult our company's technical service center, and our company will cooperate with your technical support work!