E-mail
info@qf-meter.com
- Phone
-
Address
No. 163-3 Dongfang East Road, Dongfang Avenue, Economic Development Zone, Qishuyan District, Changzhou City, Jiangsu Province
Changzhou Chengfeng Flow Meter Co., Ltd
info@qf-meter.com
No. 163-3 Dongfang East Road, Dongfang Avenue, Economic Development Zone, Qishuyan District, Changzhou City, Jiangsu Province
| CF2318 seriesLevel transmitterUsing high-precision and high stability diffusion silicon pressure sensing components, the liquid level signal of the measured liquid is converted into a 4-20mADC standard electrical signal through a highly reliable amplification circuit and precise temperature compensation. High quality sensors, exquisite packaging technology, and sophisticated assembly processes ensure the excellent quality and optimal performance of this product. This product is a split structure type and has two types of medium measurement: cable and anti-corrosion agent. Anti corrosive products can resist the erosion of various corrosive liquids and meet the needs of customers to the greatest extent possible. The CF2318 series liquid level transmitter products are divided into two types: ordinary type and intrinsic safety explosion-proof type. Explosion proof products can be widely used in various harsh and dangerous places in industrial sites. |
|
| 0-1.3 m to 0-1.5 m split-type Cable type, anti-corrosion type Lightning protection and radio frequency interference prevention Reverse polarity protection and current limiting protection Intrinsically safe explosion-proof Zero point and external continuous adjustable range High precision, high stability, high reliability HART communication protocol can be selected |
Overload pressure 2 times the maximum range output signal 4-20 m A D C (two-wire system) Working Voltage 14-36V DC (two-wire system) standard 24V DC ± 5%, ripple less than 1% medium temperature - 2 0℃~+ 8 5℃ ambient temperature - 2 0℃ ~+ 8 5℃ |
| Industrial field liquid level measurement and control Hydrological monitoring and control Navigation and shipbuilding Urban water supply and sewage treatment Dajiang Dam and Water Conservancy Construction Chemical and medical equipment |
|
| measuring medium Water and general non corrosive liquids (cable type) Various corrosive liquids (corrosive type) measurement range 0~0 . 3 m to 0~350 m (see selection table) |
load resistor (4~20 m A) :R =(U-14)0.02-R0 Among them: U is the power supply voltage, R0 is the internal resistance of the cable (0~10 m A) :R≤1KΩ (0~5V): R≥300Ω |