CLSG vertical biomass pellet atmospheric hot water boiler

NegotiableUpdate on 09/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The boiler is designed with high thermal efficiency, good smoke and dust removal effects, operates without pressure, is safe and reliable, saves fuel, and can burn for several hours with one fuel addition, reducing the labor intensity of the stoker. While meeting the heating requirements, it can also provide hot water, bathing, and showering. If some simple facilities are added, it can also steam rice and disinfect. The boiler has a small volume, compact structure, light weight, beautiful appearance, and is easy to transport, install, use, and maintain as a whole (all heating surface pipes are straight pipes, and there are sufficient hand hole devices for manual mechanical cleaning of dirt and internal inspection). Atmospheric pressure boilers operate without pressure, therefore have no safety hazards, are not limited by boiler monitoring procedures, and can be installed in living areas. In recent years, they have been rapidly developed and promoted.

Product Details

The CLSG type vertical atmospheric pressure active grate biomass hot water boiler is a multi-purpose vertical fixed grate hot water boiler. The main material of the boiler is selected from high-quality carbon steel plates specifically designed for boilers, and is strictly produced, manufactured, and inspected in accordance with JB/T7985-95 "General Technical Conditions for Atmospheric Pressure Boilers" and related standards. The boiler adopts a shell structure as a whole, consisting of a shell head, a furnace liner, a furnace liner top, a lower sealing ring, a soaring tube, and a transverse water pipe. A transverse tension brace is specially designed to enhance the strength of the furnace body; The combustion chamber is arranged inside the furnace chamber, and the fuel is burned on a fixed grate. The high-temperature flue gas generated by the fuel is washed horizontally into the tube and then discharged into the atmosphere through the chimney and chimney.
The boiler is designed with high thermal efficiency, good smoke and dust removal effects, operates without pressure, is safe and reliable, saves fuel, and can burn for several hours with one fuel addition, reducing the labor intensity of the stoker. While meeting the heating requirements, it can also provide hot water, bathing, and showering. If some simple facilities are added, it can also steam rice and disinfect. The boiler has a small volume, compact structure, light weight, beautiful appearance, and is easy to transport, install, use, and maintain as a whole (all heating surface pipes are straight pipes, and there are sufficient hand hole devices for manual mechanical cleaning of dirt and internal inspection). Atmospheric pressure boilers operate without pressure, therefore have no safety hazards, are not limited by boiler monitoring procedures, and can be installed in living areas. In recent years, they have been rapidly developed and promoted.
Product Features
1. Control system: The boiler adopts an intelligent microcomputer control system, which uses continuously variable speed automatic control to control the feeding speed, ensuring stable and rapid temperature rise. The controller has functions such as temperature setting, cycle control, time setting, and fault alarm.
2. Efficient and energy-saving: This boiler has two combustion processes, one is the combustion of coal gasification fuel itself, and the other is the gasification and combustion process of combustible mixed gas produced by the fuel in a closed and high-temperature state. The reasonable design structure of the boiler ensures a smooth, sufficient, and safe gasification process of the fuel, and adopts reverse gasification combustion for safe combustion. Energy saving devices can also be selected to achieve a thermal efficiency of over 80% and exhaust gas temperature below 160 degrees.
3. Energy saving and environmental protection: smoke-free and safe combustion of fuel.
4. Safety: The boiler operates under normal pressure without the need for annual inspection or professional stoker operation.
5. Excellent insulation performance: The boiler adopts overall insulation to reduce heat loss.
6. Hot water cleaning: Anti rust treatment inside the boiler can provide clean hot water for daily use.
Technical Parameters 1
Specifications and Parameters unit CLSG0.07 CLSG0.12 CLSG0.15 CLSG0.24
Rated heating capacity Mw/h 0.07 0.12 0.15 0.24
outlet water temperature 85 95 95 95
return water temperature 60 70 70 70
work pressure MPa 0 0 0 0
heating surface area 1.5 6 7 10
Design thermal efficiency % 72 72 72 72
Furnace grate diameter M 0.45 0.55 0.65 0.85
Combustion consumption Kg/h December 15th 17-22 21-28 39-47
Net weight kg 216 612 728 1005
Overall dimensions mm 700×2100 800×2300 900×2400 1012×3200

Technical parameter 2
Specifications and Parameters unit CLSG0.35 CLSG0.48 CLSG0.7 CLSG1.05
Rated heating capacity Mw/h 0.35 0.48 0.7 1.05
outlet water temperature 95 95 95 95
return water temperature 70 70 70 70
work pressure MPa 0 0 0 0
heating surface area 23 32 53 60
Design thermal efficiency % 72 72 72 74
Furnace grate diameter M 0.95 1.15 1.35 1.55
Combustion consumption Kg/h 62-69 86-95 126-138 186-198
Net weight kg 1893 2550 3821 4830
Overall dimensions mm 1200×3400 1400×3700 1612×4421 1812×4500

Technical parameter three
Specifications and Parameters unit CLSG1.4 CLSG1.75 CLSG2.1 CLSG2.8
Rated heating capacity Mw/h 1.4 1.75 2.1 2.8
outlet water temperature 95 95 95 95
return water temperature 70 70 70 70
work pressure MPa 0 0 0 0
heating surface area 79 98 138 177
Design thermal efficiency % 74 74 74 74
Furnace grate diameter M 1.75 1.75 1.97 2.25
Combustion consumption Kg/h 248-262 310-336 372-394 496-523
Net weight kg 6784 7519 8158 11030
Overall dimensions mm 2016×4860 2016×5500 2216×5554 2520×5555

All the above models of boilers are used under normal pressure, and an expansion water tank must be installed during installation. The atmospheric connection port of the boiler must be connected to the expansion water tank.
Note: For CLSG0.7MW and above models, please make a reservation if needed. The manufacturing cycle is 5-7 days.