Local parameter setting and operation instructions
[Purpose]
Test whether various zippers can withstand the specified number of reciprocating pulling operations under the action of horizontal and vertical tension.
Compliant with standards: CNS-1083, QB/T2171~2173
During the experiment, the machine drives the zipper slider at a constant speed, making 30 reciprocating movements per minute until the specified number of times is reached. The condition of the test sample is checked to determine the product performance.
Reciprocal stroke: 75mm;
Horizontal clamping device width: 25mm
Total weight of longitudinal clamping device: 0.28-0.34kg;
Distance between two clamping devices: 6.35mm;
Counter: electronic 0~999999;
Volume: 28 × 55 × 66 (W × D × H);
Weight: approximately 50kg;
Operating instructions
1. Prepare the test piece:
1. Customers make test specimens according to their own requirements (According to standards)
2. Preparation for the experiment:
1. Determine before testing:
1.1 Confirm whether the power supply meets the specified requirements
1.2 Place the test piece on the workbench and clamp it properly
III. Experimental Steps:
1. Plug in the power supply (AC220V, 3A);
2. Turn on the power switch
3. Set the required number of experiments on the counter
Schematic diagram of operation panel

POWER:Power button, turn on/off the power of the instrument
RUN:start key
STOP:stop key
CLR:Reset key to reset the value to zero
SET:Set key, transition from normal state to modified state, modify test times, and finally confirm and return to normal state.
↑ Numerical increment key
↓ Numerical decrement key
← Left Shift Key
→ Right shift key

Fig 3
As shown in the picture:
SP:test speed
TM:The set number of tests
ADD TIMES:Actual number of tests
Turn on the power and pressSETKey, display window as shown in the following figure

Figure 4
Press the ↑↓ keys again to change the counting method, where O is positive and 1 is negative
Press the ←→ key again to enter the set number of times to modify, move to the corresponding position that needs to be modified, and then use the ↑↓ keys to increase or decrease. After setting the required number of tests, pressSETPress the key to exit the modification state. After setting, pressRUNThe key starts the test, and the instrument automatically stops after completing the set number of movements. If you need to stop halfway, pressSTOPThe key. Press againRUNContinue testing with the key. Before conducting the next test, the following steps should be takenCLRPress the key to reset the record to zero.
4. When the number of experiments reaches the set value, the machine stops
5. Repeat the test for the next product or turn off the power
At the end of the test, record the test results
Preparation for the experiment:
1. Set the governor switch to the lowest position
2. Turn on the power switch and adjust the speed regulator to an appropriate speed of 30 times per minute.
3. According to the set number of items, the entire machine is in a testing state after reaching the specified number of times
4. Fix the test sample in the testing fixture
Test method for load pull times
Testing equipment and fixtures
The testing equipment consists of a set of fixtures, a reciprocating transmission system, and a display system.
The instrument has a reciprocating frequency of 30 times/min, a stroke of 75 mm, and an opening and closing angle of 30 degrees and 60 degrees
Test range: Zipper specifications within 3.5m m-12mm
The test fixture has a horizontal width of 25mm and a vertical width of 10mm, with a clamping surface tooth profile angle of 60 ° and a pitch of 1.5mm
Testing methods and steps
Take a zipper sample with a length of 250 mm or more, and wipe the front and back surfaces twice with paraffin wax.
Check the testing machine, keep the pull tab fixture at the lower limit, clamp the zipper on the five fixed points, and pull the tab
Fixed (see Figure 12)
testing procedure
First, roughly fix the tail end (bottom end) of the zipper onto the fixing point A (pull tab inward)
Fix the pull tab onto the pull tab fixture
Fix the front end (top end) of the zipper at points D and E:
Release the fixing point A, pull up the end of the zipper so that the fixing pin falls in the middle of the balance plate hole, and then clamp point A (at this point, visually inspect points D and E on the same horizontal line)
Release the horizontal clamping blocks B and C, and insert the cloth strips on both sides of the zipper tape into the B and C fixtures for clamping. The distance between the clamping mouth and the tooth foot is about
5 nun, At this point, the five fixed points have been fixed;
Set the zipper to the upper limit, release the zipper clamp, and visually inspect whether the zipper remains straight. If it does not meet the requirements, readjust until all clamping is completed;
Zippers of different specifications should be loaded horizontally and vertically according to the specified requirements (see Table 5)



5. After the test is completed, turn off the power and remove the test product. After rubbing, clean the machine
Shanghai Qingbo Experimental Equipment Co., Ltd. Main Products:
1、 Environmental detection equipment: constant temperature and humidity test chamber, damp heat test chamber, programmable constant temperature and humidity test chamber, high and low temperature alternating damp heat test chamber, temperature and humidity regulating test chamber, single point constant temperature and humidity test machine, walk-in constant temperature and humidity room, high and low temperature test chamber, high temperature aging room, various precision ovens, cold and hot shock test chamber, brine spray test chamber, salt fog test machine, sulfur dioxide test chamber, rain test chamber, sand dust test chamber, yellowing resistance test chamber, sunlight test chamber, ultraviolet light aging test chamber, xenon lamp aging test chamber, ozone aging test chamber, mold test chamber and other environmental test chambers, UV furnace, etc.
2、 Material mechanics testing equipment: tensile testing machine, microcomputer controlled universal material testing machine, drop testing machine, ball impact testing machine, mechanical vibration table, high-frequency vibration testing table, low-frequency vibration testing table, electromagnetic vibration testing table, simulated automobile transportation vibration table, wire bending testing machine, mobile phone flip life testing machine, mobile phone slide life testing machine, button life testing machine, friction decolorization testing machine, alcohol friction resistance testing machine, TABER wear resistance testing machine, DIN wear resistance testing machine, RCA paper tape wear resistance testing machine, insertion and extraction life testing machine, fully automatic insertion and extraction force testing machine, load displacement curve testing machine, shaft life testing machine, wire tension testing machine, elongation testing machine, etc.
3、 Luggage testing equipment: rupture strength testing machine, cardboard box compression testing machine, cardboard box compression testing machine, ring compression strength testing machine, edge compression strength testing machine, peel strength testing machine, cantilever beam impact testing machine, simply supported beam impact testing machine, drop ball impact testing machine, drop hammer impact testing machine, zipper reciprocating testing machine, button tension testing machine, leather scratch resistance testing machine, leather softness testing machine, horizontal and vertical fire resistance testing machine, etc.
4、 Measurement equipment and other laboratory equipment: X-ray fluorescence spectrometer, ROHS Detector, element analyzer, manual Rockwell hardness tester, electric Rockwell hardness tester, digital Rockwell hardness tester, portable Rockwell hardness tester, surface Rockwell hardness tester, digital surface Rockwell hardness tester, Vickers hardness tester, micro Vickers hardness tester, low load Vickers hardness tester, digital micro Vickers hardness tester, Brinell hardness tester, Blowe hardness tester, Vickers hardness tester, Richter hardness tester, Babbitt hardness tester, Shore hardness tester, metallographic sample cutting machine, metallographic sample pre grinding machine, metallographic sample polishing machine, metallographic sample embedding machine, metallographic microscope, visual microscope, projector, image measuring instrument, coordinate measuring instrument, plastic melting index meter, rotorless vulcanizing instrument, needle testing machine Color difference meter, portable color difference meter, spectrophotometer, color matching light box, standard light source box, hundred grid knife, pencil hardness tester, Tape retention testing machine, tape initial adhesion testing machine, push-pull force meter, ink decolorization testing machine, etc.