CWNS type horizontal fuel and gas atmospheric hot water boiler

NegotiableUpdate on 09/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The boiler body is strictly produced, manufactured, and inspected in accordance with JB/T7985-95 "General Technical Conditions for Atmospheric Pressure Boilers" and related standards. The high-quality boiler is equipped with multiple safety protections (combustion, overheating, ultra-low water level, shutdown, shutdown, program start protection, etc.), and the gas is equipped with low pressure and leakage alarms. Advanced intelligent control technology enables remote operation monitoring and fault diagnosis. Multiple boilers can be designed for centralized control.

Product Details

The fully automatic fuel and gas hot water boiler is a combustion tube boiler with a lower burner. Fuel gas and oil are sprayed and atomized by a burner and then burned under slight positive pressure in a vertical straight furnace chamber. High temperature flue gas rushes upward along the furnace chamber to wash the heating surface of the smoke pipe, and after convective heat exchange, it reaches the upper smoke box and is discharged into the atmosphere through the chimney. The boiler is equipped with imported burners and fully automated program control, with a high degree of automation, which can achieve the best combustion effect for the boiler. This furnace model is equipped with original imported burners, fully simulated and controlled by a computer. The heating surface and flue gas flow have been fully optimized, resulting in a more compact structure and easier installation and maintenance. Adopting advanced centrifugal glass wool multi-layer insulation, with minimal heat loss; Imported colored steel plate packaging, with a beautiful appearance. It can provide heating and domestic hot water for hotels, schools, bathhouses, and other enterprises and institutions.
The boiler body is strictly produced, manufactured, and inspected in accordance with JB/T7985-95 "General Technical Conditions for Atmospheric Pressure Boilers" and related standards. The high-quality boiler is equipped with multiple safety protections (combustion, overheating, ultra-low water level, shutdown, shutdown, program start protection, etc.), and the gas is equipped with low pressure and leakage alarms. Advanced intelligent control technology enables remote operation monitoring and fault diagnosis. Multiple boilers can be designed for centralized control.
1. The boiler smoke pipe is equipped with turbulence fins to enhance heat transfer, thereby reducing the convective heating area and lowering the boiler cost.
2. This boiler adopts a new type of insulation material, which has good insulation performance, light weight, and low cost.
3. The entire boiler system is safe and reliable, and the boiler is equipped with overpressure safety protection devices such as safety valves, which can make the boiler operation safer and more reliable.
4. After various furnace designs, demonstrations, and technical comparisons, this series of boilers has a more reasonable structure and superior performance.
Performance characteristics:
1. The time setting function enables the boiler to start and stop within the set time.
2. Overheating protection: When the water temperature inside the boiler exceeds the limit, the burner will be automatically prohibited from working and an alarm will be triggered.
3. Secondary overheat protection: When the temperature of the boiler shell exceeds 105 ℃, the secondary circuit will be automatically cut off, and it will reset automatically after normal operation.
4. Real time monitoring of water level: Boiler low water level cuts off the burner for protection.
5. Users can set the boiler's water supply temperature according to their load requirements to reduce operating costs.
6. The inlet/outlet temperature display function makes it more convenient to monitor the operation status of the boiler and system.
structural characteristics
The boiler body adopts a three pass design, with extremely high thermal efficiency, and is widely used for heating and hot water supply users.
The product operates without pollution, noise, and is a green and environmentally friendly product.
The combustion system adopts Italian imported combustion engines, equipped with flameout protection, water shortage protection, and ultra-high temperature protection, providing comprehensive safety protection.
The control system adopts an intelligent computer controller, which has automatic control functions such as water replenishment, combustion, and circulation control, and is easy to operate. The water temperature control is equipped with automatic control functions such as digital temperature display, temperature control, and over temperature protection. Users can freely set the water temperature between 30 ℃ and 90 ℃ to ensure energy efficiency.
Equipped with time control function, the on/off time can be set arbitrarily according to user needs, and faults can be automatically recorded for easy maintenance.
Compact structural design, imported color board, beautiful and generous, not easy to rust, and occupies a small installation area.
Technical Specifications:
Parameters/Data model model model
WNS0.35-0.7/95/70-Y、Q WNS0.7-0.7/95/70-Y、Q WNS1.05-0.7/95/70-Y、Q
Rated thermal power MW 0.35 0.7 1.05
Rated working pressure MPa 0.7 0.7 0.7
Rated outlet water temperature 95 95 95
Rated inlet water temperature 70 70 70
Heating surface area of boiler body m2 15 28.9 41.8
flue gas temperature 165 165 165
Thermal efficiency of gas boiler % ≈93 ≈93 ≈93
Applicable fuel / Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas
Ringman blackness / <Level 1 <Level 1 <Level 1
fuel consumption light oil kg/h 31 62.2 93.66
natural gas Nm3/h 36 72.1 108.23
liquefied gas Nm3/h 12.6 25.2 37.8
Urban gas Nm3/h 72 144 216.5
Burner selection brand / Wesso and Ouke from Germany; Finland's Olin, Italy's Riyalu, Bader, Univas; Johnson&Johnson in the United States; Wuxi Mankenet
Model of water supply pump / JGGC2-8x10 JGGC2 - 8x10 JGGC2-8x14
Feed water pump power kw 1.5 1.5 2.2
Use power supply V 380V/50Hz 380V/50Hz 380V/50Hz
Boiler water volume m3 2 3.5 5.3
Boiler host transportation weight t 3.1 5.2 7.6
Boiler transportation dimensions (length x width x height) m 3.2x1.8x1.9 3.5x2x2.3 3.7x2.2x2.5
Diameter of outlet valve (DN) mm 65 80 100
Return valve diameter (DN) mm 65 80 80
Chimney diameter (Φ) mm 316 316 400
Boiler back pressure Pa 180 190 500

Parameters/Data model model model
WNS1.4-0.7/95/70-Y、Q WNS2.1-0.7/95/70-Y、Q WNS2.8-1.0/95/70-Y、Q
Rated thermal power MW 1.4 2.1 2.8
Rated working pressure MPa 0.7 0.7 1
Rated outlet water temperature 95 95 95
Rated inlet water temperature 70 70 70
Heating surface area of boiler body m2 56.6 91.8 125.1
flue gas temperature 160 158 155
Thermal efficiency of gas boiler % ≥93 ≥93 ≥93
Applicable fuel / Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas
Ringman blackness / <Level 1 <Level 1 <Level 1
fuel consumption light oil kg/h 124.75 187.11 249.21
natural gas Nm3/h 144.16 216.21 287.98
liquefied gas Nm3/h 50.68 76.01 101.24
Urban gas Nm3/h 288.3 432.2 575.96
Burner selection brand / Wesso and Ouke from Germany; Finland's Olin, Italy's Riyalu, Bader, Univas; Johnson&Johnson in the United States; Wuxi Mankenet
Model of water supply pump / JGGC2-8x17 JGGC4-8x13 JGGC4-8x13
Feed water pump power kw 3 3 3
Use power supply V 380V/50Hz 380V/50Hz 380V/50Hz
Boiler water volume m3 6.3 7.6 9.6
Boiler host transportation weight t 8.8 11 14.5
Boiler transportation dimensions (length x width x height) m 4.4x2.2x2.5 4.7x2.2x2.9 5.3x2.5x2.9
Diameter of outlet valve (DN) mm 100 100 100
Return valve diameter (DN) mm 80 40 40
Chimney diameter (Φ) mm 400 530 530
Boiler back pressure Pa 540 800 850

Parameters/Data model model model
WNS3.5-1.0/115/70-Y、Q WNS4.2-1.0/115/70-Y、Q WNS5.6-1.0/115/70-Y、Q
Rated thermal power MW 3.5 4.2 5.6
Rated working pressure MPa 1 1 1
Rated outlet water temperature 115 115 115
Rated inlet water temperature 70 70 70
Heating surface area of boiler body m2 135.3 135.3 161
flue gas temperature 158 168 162
Thermal efficiency of gas boiler % ≥93 ≈93 ≈93
Applicable fuel / Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas
Ringman blackness / <Level 1 <Level 1 <Level 1
fuel consumption light oil kg/h 311.17 373.41 497.78
natural gas Nm3/h 359.58 431.5 575.2
liquefied gas Nm3/h 126.41 151.7 202.2
Urban gas Nm3/h 719.16 863 1151
Burner selection brand / Wesso and Ouke from Germany; Finland's Olin, Italy's Riyalu, Bader, Univas; Johnson&Johnson in the United States; Wuxi Mankenet
Model of water supply pump / JGGC4-8x21 JGGC4-8x21 JGGC4-8x21
Feed water pump power kw 4 4 4
Use power supply V 380V/50Hz 380V/50Hz 380V/50Hz
Boiler water volume m3 11.7 12.5 12.6
Boiler host transportation weight t 16.1 16.6 21
Boiler transportation dimensions (length x width x height) m 5.8x2.6x2.9 6.1x2.6x2.9 5.4x2.9x3.3
Diameter of outlet valve (DN) mm 150 150 150
Return valve diameter (DN) mm 150 150 150
Chimney diameter (Φ) mm 530 530 680
Boiler back pressure Pa 1080 1280 1200

Parameters/Data model model model
WNS7-1.0/115/70-Y、Q WNS10.5-1.0/115/70-Y、Q WNS14-1.25/115/70-Y、Q
Rated thermal power MW 7 10.5 14
Rated working pressure MPa 1 1 1.25
Rated outlet water temperature 115 115 115
Rated inlet water temperature 70 70 70
Heating surface area of boiler body m2 184 334.8 375
flue gas temperature 162 164 165
Thermal efficiency of gas boiler % ≈93 ≈93 ≈93
Applicable fuel / Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas Light oil, natural gas, liquefied gas, city gas
Ringman blackness / <Level 1 <Level 1 <Level 1
fuel consumption light oil kg/h 621 931.5 1242
natural gas Nm3/h 719.17 1078 1438.3
liquefied gas Nm3/h 252.18 378.27 504
Urban gas Nm3/h 1438 2157 2876
Burner selection brand / Wesso and Ouke from Germany; Finland's Olin, Italy's Riyalu, Bader, Univas; Johnson&Johnson in the United States; Wuxi Mankenet
Model of water supply pump / JGGC4-8x21 JGGC8-8x21 JGGC8-8x21
Feed water pump power kw 4 5.5 5.5
Use power supply V 380V/50Hz 380V/50Hz 380V/50Hz
Boiler water volume m3 14.7 24.7 37.5
Boiler host transportation weight t 22.8 38.8 46
Boiler transportation dimensions (length x width x height) m 6.1x2.9x3.3 7.1x3.2x3.7 7.7x3.2x3.7
Diameter of outlet valve (DN) mm 150 200 250
Return valve diameter (DN) mm 150 200 250
Chimney diameter (Φ) mm 680 850 1000
Boiler back pressure Pa 1200 1600 100
Note: Fuel consumption calculation: Diesel fuel is calculated based on a low calorific value of 10250kcal/kg; Natural gas (LNG) has a low calorific value of 8700kcal/Nm3;
Liquefied petroleum gas (LPG) has a low calorific value of 25800 kcal/Nm3; City gas (CG) has a low calorific value of 4000kcal/Nm3.
Note: All data in the table areBoiler No