Coal safety explosion-proof mining multi turn valve electric device

NegotiableUpdate on 12/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The coal safety explosion-proof type mining multi turn valve electric device is used for opening, closing, and regulating valves (equipped with a dedicated valve explosion-proof control box), and is a driving device for remote control, centralized control, and self-control of valves.
Product Details

1Coal safety explosion-proof mining multi turn valve electric deviceIntroduction

The ZB series explosion-proof multi turn valve electric device is mainly suitable for use with valves that perform linear motion of opening and closing components, such as gate valves, globe valves, diaphragm valves, gates, water gate valves, etc. It is used to open, close, and adjust valves (equipped with a dedicated valve explosion-proof control box), and is a driving device for valves to achieve remote control, centralized control, and self-control. It has the characteristics of comprehensive functionality, reliable performance, advanced control system, small size, light weight, and easy use and maintenance.

The performance of this product complies with the provisions of GB3836.1-2010 "Electrical Equipment for Explosive Gas Environments Part 1: General Requirements", GB3836.2-2010 (Electrical Equipment for Explosive Gas Environments Part 2: Explosion proof Type "d '"), GB3836.3-2010 "Electrical Equipment for Explosive Gas Environments Part 3: Increased Safety Type" e' (idt I EC 60079-7:1990) "and GB/T24922-2010" Technical Conditions for Explosion proof Valve Electric Devices ". This product has been verified by the National Explosion proof Electrical Product Quality Supervision and Inspection Testing Center and has obtained a full series of explosion-proof certificates, which can be widely used in most explosive gas environments.

Working principle and type

The ZB series electric device adopts an explosion-proof shell to separate the circuit parts that may generate sparks and arcs from the explosive gas mixture outside the shell, thereby achieving the purpose of explosion-proof. The parameters of the explosion-proof joint surface comply with the provisions of GB3836.2-2010, and the cable entry device complies with the provisions of GB3836.1-2010.

Explosion proof types are divided into mining explosion-proof type and ordinary explosion-proof type, with explosion-proof marks of "ExdlMb" and "Exd II BT4 Gb" respectively.

The cable entry device is of the compression nut and pressure plate type.

IICoal safety explosion-proof mining multi turn valve electric deviceExecution mechanism parameters

Specification Model

Rated three-phase voltage (V)

Output rated torque

(N • m )

Z valve stem diameter

(mm )

manual

speed ratio

output speed

(r/min )

Motor power

(kW)

Output axis Z is large

Number of rotations

Reference weight

(kg )

ZB10

AC 380/660

100

28

32:1

24

0.25

150

50

ZB15

AC 380/660

150

28

32:1

24

0.37

150

50

ZB20

AC 380/660

200

40

32:1

18

0.37

150

53

ZB30

AC 380/660

300

40

32:1

18

0.55

150

53

ZB45

AC 380/660

450

48

25:1

24

1.1

150

85

ZB60

AC 380/660

600

48

25:1

24

1.5

150

95

ZB90

AC 380/660

900

60

25:1

24

2.2

150

112

ZB120

AC 380/660

1200

60

25:1

24

3

150

112

3、 Precautions for use

1. The installation form of this electric actuator has no principle requirements, but the recommended installation form is when the motor is in a horizontal state and the electrical box cover is in a horizontal or vertical upward state, which is beneficial for lubrication, debugging, maintenance, and manual operation;

2. During installation, the space required for maintenance and inspection personnel to disassemble each component should be ensured;

3. The axial clearance between the installation and valve connection teeth should not be less than 1-2mm;

4. When used for open stem valves, the extension of the valve stem should be checked to ensure that it matches the length of the valve stem sheath;

5. During installation, disassembly, and debugging, the sealing surface, sealing components, and explosion-proof surface of the explosion-proof electric actuator should not be damaged, and anti rust oil should be applied to the explosion-proof surface;

6. When disassembly is required, the manual handwheel should be rotated several times before proceeding with the valve slightly open;

7. Before installation, check whether the explosion-proof mark on the nameplate is consistent with the installation environment;

8. The grounding screw on the junction box must be reliably grounded with a grounding wire;

9. The strength of the connecting screws between the electric device and the valve should be grade 8.8;

10. When lifting electric devices, a reasonable lifting position should be selected to avoid falling, bumping, and other phenomena;

11. Open the junction box, use a wrench to unscrew the compression nut of the cable entry device, firmly connect the cable to the terminal block in the junction box, confirm that there are no errors, cover the junction box with the top cover, and tighten the fastening screw. The terminal connection should be secure, and the wire should be clamped with an elbow according to the method shown in Figure 10. The junction box has four entry devices, one for motor power cables and three for control cables. The power cables used must have grounding wires and be connected to the grounding terminals on the junction panel. The diameter specifications of the introduced cable are shown in Table 5. After connecting the wire, a tight sealing ring should be installed, and the Shore hardness of the sealing ring should be 45-55 degrees. Damaged or aged sealing rings should be replaced in a timely manner.