DAVIS weather station Modbus RTU/TCP gateway

NegotiableUpdate on 12/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
DAVIS weather station Modbus RTU/TCP gateway KTA-382 Modbus gateway can easily connect PLC, RTU or SCADA systems to one of the following Davis weather stations through Modbus RTU or TCP: $r $n $r $n ● Wired Vantage Pro 2 $r $n $r $n ● Wired Vantage Pro 2 Plus $r $n $r $n ● Wireless Vantage Pro 2 $r $n $r $n ● Wireless Vantage Pro 2 Plus
Product Details

DAVISweather stationModbus RTU/TCP gatewaynew-typeKTA-382Combined with beforeKTA-282andGWY-141The function of the model. It connects the weather station of DAVIS Instrument Company toModbusNetwork, supportTCPandRTUagreement. providePoEPower version.

DAVIS气象站 Modbus RTU/TCP 网关


description

KTA-382 ModbusThe gateway can be accessed throughModbus RTUorTCPTranslate into EnglishPLCTheRTUorSCADAThe system easily connects to one of the following Davis weather stations:

wiredVantage Pro 2

wiredVantage Pro 2 Plus

wirelessVantage Pro 2

wirelessVantage Pro 2 Plus

Gateway through DavisWeatherLinkCable (used forVantage ProThe serial versionWeather Link)Connect to the control panel of the weather station and use it asModbus TCP/IPorRTUFrom Station toModbusPart of the network. So, yourSCADAOther systems or networksModbusThe device can monitor and take action based on data such as wind speed, direction, and temperature.

If you are looking for a complete solution, please check out ourModbusMeteorological station kit. They possessBACnetEverything needed to obtain weather station data online.

Ordering information:

KTA-382Sstandard form

KTA-382Pstandard form+ PoE

DAVISweather stationModbus RTU/TCP gatewaySpecifications

power supply 12 to36Vdirect current

power waste:12Vtime1.2W24Vtime0.96W

Operating Temperature 0 to70°C

2 xAlarm output(Open CollectionOutput)

agreement:

Through EthernetModbus TCP/IPNetwork. Can accept up to multiple at the same timeModbusPolling of the main station.

Can be accessed through two independent serial portsRS-485pullModbus RTU.

Provide web pages andPCApplication, easy to configureTCPandRTUset up. It can also display the current settings and weatherData and communication status

Provided additional436The height of bytes/Low historical and current data.

size115L × 90W × 40H (mm)

It can be fixed on the panel with screws or installed onDINOn the guide rail.