| Technical Specifications |
| Model DP |
10212/24 |
15212/24/48 |
20212/24/48 |
30224/48 |
35224/48 |
40224/48 |
50248 |
60248 |
70248 |
| rated power |
1000W |
1500W |
2000W |
3000W |
3500W |
4000W |
5000W |
6000W |
7000W |
| Peak power (20ms) |
3000W |
4500W |
6000W |
9000W |
10500W |
12000W |
15000W |
18000W |
21000W |
| starter motor |
1HP |
1.5HP |
2HP |
3HP |
3HP |
3HP |
4HP |
4HP |
5HP |
| Standard battery voltage |
12/24VDC |
12/24/48VDC |
24/48VDC |
24/48VDC |
48VDC |
| Machine size (L * W * Hmm) |
555*297*184 |
615*315*209 |
| Packaging size (L * W * Hmm) |
620*345*255 |
680*365*280 |
| Net weight (kg) |
12 |
13 |
15.5 |
18 |
19 |
23 |
24.5 |
26 |
27.5 |
| Gross weight (kg) (cardboard packaging) |
14 |
15 |
17.5 |
20 |
21 |
25.5 |
27 |
28.5 |
30 |
| Installation method |
wall-mounted |
| General Parameters |
| input |
DC input voltage range |
10.5-15VDC (single battery voltage) |
| Range of mains input voltage |
85VAC~138VAC / 170VAC~275VAC / 180VAC~285VAC / 190VAC~295VAC |
| Frequency range of mains power input |
45Hz~65Hz |
| Maximum mains charging current |
0~30A (depending on the model) |
| Municipal power charging method |
Three stage (constant current, constant voltage, float charging) |
| output |
Inverter output efficiency |
≥85% |
| Inverter output voltage |
110VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% |
| Inverter output frequency |
50/60Hz±1% |
| Inverted output waveform |
pure sine wave |
| Efficiency of mains power output |
>99% |
| Output voltage range of mains power |
110VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% |
| Frequency range of mains power output |
automatic tracking |
| Distortion degree of inverse waveform |
≤ 3% (linear load) |
| Battery mode no-load loss |
≤ 0.8% rated power |
| No load loss in mains mode |
≤ 2% rated power (mains charger not working) |
| Energy saving mode no-load loss |
≤10W |
| protect |
Battery undervoltage alarm |
11V/single cell battery; Lithium battery 9.5V/ternary lithium, 3S (12V system; 24V system x2; 48V system x4) |
| Battery undervoltage protection |
10.5V/single cell battery; Lithium battery 9V/ternary lithium, 3S (12V system; 24V system x2; 48V system x4) |
| Battery overvoltage alarm |
Lead acid battery: 15V (12V system; 24V system x2; 48V system x4) |
| Battery overvoltage protection |
Lead acid battery: 17V (12V system; 24V system x2; 48V system x4) |
| Battery overvoltage recovery voltage |
Lead acid battery: 14.5V (12V system; 24V system x2; 48V system x4) |
| Overload power protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
| Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
| Temperature protection |
>90 ° C (turn off output) |
| call the police |
A |
Normal working condition, no alarm sound from buzzer |
| B |
When there is a battery failure, abnormal voltage, or overload protection, the buzzer will beep 4 times per second |
| C |
When the machine is turned on for the first time and functioning normally, the buzzer will sound 5 times |
| working mode |
Inverter priority/mains priority/energy-saving mode |
| Convert time |
≤4ms |
| panel display |
LCD (optional external screen) |
| Communication function (optional) |
RS232/RS485 communication interface/mobile app (WIFI monitoring or GPRS monitoring) |
| environment |
Operating temperature |
-10℃~40℃ |
| Storage temperature |
-15℃~60℃ |
| noise |
≤55dB |
| altitude |
2000m (use with reduced rating if exceeded) |
| relative humidity |
0%~95%, no condensation |
| Note: Please contact the sales consultant to obtain the latest product specifications |