Desktop Xenon Lamp Weathering and Aging Test Chamber

NegotiableUpdate on 12/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The desktop xenon lamp weathering aging test chamber uses a xenon arc lamp that can simulate the full sunlight spectrum to reproduce the destructive light waves present in different environments, providing corresponding environmental simulation and accelerated testing for scientific research, product development, and quality control.
Product Details

Desktop Xenon Lamp Weathering and Aging Test ChamberThe use of xenon arc lamps that can simulate the full spectrum of sunlight to reproduce destructive light waves in different environments can provide corresponding environmental simulation and accelerated testing for scientific research, product development, and quality control.
The SN xenon lamp test chamber can be used for selecting new materials, changing existing materials, or evaluating durability changes after material composition changes. It can simulate the changes in materials exposed to sunlight under different environmental conditions very well.
Conduct aging tests by exposing material samples to xenon arc lamp illumination and thermal radiation To evaluate the light and weather resistance of certain materials under high-temperature light sources Mainly used in automobiles, coatings, plastics, pigments, adhesives, fabrics, etc

Desktop Xenon Lamp Weathering and Aging Test ChamberTechnical Specifications
SN-66 internal dimensions 380 × 500 × 350 external dimensions 520 × 770 × 630

1. Sample tray size: 251 × 457mm
2. Blackboard temperature: 63-100 ℃± 3 ℃
3. Temperature fluctuation: ≤± 0.5 ℃
4. Temperature uniformity: ≤± 2.0 ℃
5. Glass window filter: 1 piece
6. Xenon lamp source: air-cooled lamp tube
7. Xenon lamp quantity: 1 unit
8. Rainfall time: Continuous rainfall adjustable
9. Rainfall cycle: 0-240min, adjustable interval (intermittent) rainfall
10. Spray cycle (spray time/no spray time): 18min/102min
11. Rainwater pressure: 0.12-0.15Mpa
12. Spray nozzle aperture: Ø 0.8mm
13. Xenon lamp power: 1.8 × 1
14. Heating power: 2KW
15. Distance between sample holder and lamp: 230-280mm
16. Wavelength: 290-800nm
17. The illumination period is continuously adjustable, with a time range of 1 to 999h, m, s, and an irradiance of 60W/m2. The maximum Z value does not exceed 130W/m2 (the average irradiance of ultraviolet light with a spectral wavelength of 290nm to 400nm). When the UV spectral wavelength is below 300nm, the maximum Z value does not exceed 2W/m2

Introduction to Structural Design
1. Main body part
2. Heating section
3. Display control section
4. Air conditioning section
5. Safety protection measures section
6. Other attachment parts

Box making material
1. The outer shell is processed and formed using high-quality (t=1mm) A3 steel plate CNC machine tools, and the surface of the shell is sprayed with plastic for a smoother and more beautiful appearance. (Now upgraded to rounded corners)
2. The inner liner is made of imported (t=1mm) high-quality 304 stainless steel plate.
3. Insulation: Hollow insulation layer
4. Double layer high temperature resistant high tension sealing strips are used between the door and the box to ensure the sealing of the testing area. 5. Double layer high temperature resistant high tension sealing strips are used between the door and the box to ensure the sealing of the testing area
5. Using non reactive door handles makes operation easier

Circuit control system
1. The temperature and humidity control instrument adopts a fully imported high-precision digital display microcomputer integrated controller from South Korea.
2. Accuracy: 0.1 ℃ (display range)
3. The output power of temperature and humidity control is calculated by a microcomputer to achieve high-precision and high-efficiency electricity consumption

lighting system
1. Blackboard thermometer: metal blackboard thermometer;
2. Xenon lamp tube: Imported Q-Panel lamp tubes that have passed inspection, with a lifespan of 1600-2000 hours.

Water spray circulation system
1. Water quality: Deionized water (solid content less than 20ppm)
2. Equipped with water level display for the storage tank
3. The sprayed water has recyclability
4. The spray pressure can be adjusted between 0.12 and 0.15 Mpa
5. Two nozzles were installed at the top of the studio
protection system
1. Overtemperature protection
2. Overheating of water pump, overcurrent protection
3. Other issues include electrical leakage
4. Automatic shutdown after fault alarm

Random materials
1. Instruction manual, warranty card
2. Operation method, precautions, basic shipping accessories, maintenance and repair matters

Equipment usage conditions
1. Environmental temperature: 5 ℃~+28 ℃ (average temperature within 24 hours ≤ 28 ℃)
2. Environmental humidity: ≤ 85%
33. Power requirements: AC220 (± 10%) V/50HZ single-phase three wire system
4. Pre installed capacity: 2KW

Applicable standard
This product is designed and manufactured strictly in accordance with the technical parameters of GB/T16422.2-99.