1、 Introduction
This instrument is widely used in various universities, environmental protection, scientific research, health, epidemic prevention, petroleum, metallurgy, chemical, medical and other units. According to the requirements of the majority of users, it is designed with multi connected heating, stirring and constant temperature control such as two connected, four connected, and six connected. Enable users to obtain corresponding effects and data for multiple samples simultaneously. This instrument has good performance, low noise, and significant stirring effect, making it an ideal and essential tool for laboratory technicians.
2、 Performance
1Power supply voltage:220V±10% 50HZ
2Motor power: single motor25W X2
3Hot wire power consumption: the highest for a single hot wire100W X2
4Magnetic steel speed: maximum2000turn/divide
3、 Usage method
When using this instrument, first check if all the accessories are complete, then install the fixtures in order, place the beaker that needs to be stirred in the center of the plating plate, add the solution, place the stirrer in the beaker solution, and then plug in the power plug of the instrument first. Then turn on the power speed control switch and turn on the indicator light to start working. The speed control is gradually adjusted from low speed to high speed, and it is not allowed to start directly at high speed to avoid the stirrer not being synchronized and causing jumping. Temperature control: Insert the probe into the socket and adjust the temperature control knob to the desired temperature. When not working, cut off the power supply. To ensure safety, please connect the ground wire when using. The instrument should be kept clean and dry, and it is strictly prohibited for solution to enter the machine to avoid damaging the parts and prevent severe vibration.
4、 Precautions
1When the stirrer jumps or does not stir during mixing, please cut off the power and check if the bottom of the beaker is flat and the position is correct. Please also measure if the current voltage is220Vpositive and negative10VOtherwise, the above situation will occur.
2The heating time should generally not be too long, and intermittent use can prolong the service life.
3Electricity usage: The power socket should use a three hole safety socket and must be properly grounded.
4The instrument should be kept clean and dry, and the solution should strictly flow into the machine to avoid damaging it. When not working, the power should be cut off.
This product comes with a one-year warranty and lifetime maintenance; Special products can be customized.
|