Electric motor water pump laser alignment instrument, domestic coupling alignment instrument, in stock, The NIEDOX-LASER60 laser alignment instrument is a linear laser axis alignment system that includes two components mounted on the axis
Or measuring units on both sides of the coupling. After rotating the shaft to different measurement positions, the system calculates the distance between the shafts
Offset and angular centering error.
These values will be compared with user-defined tolerance values and the machine can be adjusted immediately. measuringDuring the process, measurements will be taken from three angles with an interval of at least 20 degrees. Because the axis rotates through an arc, Ren HepingThe misalignment or angular misalignment error can cause the detector to measure the difference between their positions.Low power Bluetooth wirelessly transmits the positioning information emitted by the measurement unit to the display device, which will calculateAxis misalignment and suggest adjusting the machine feet. If the shafts of the unit are not aligned, the machine will definitely run in parallelThere is a misalignment. The actual axis position can be displayed in three-dimensional space, while the centerline can be defined mathematically,This makes it easier to identify whether the relationship between the shaft and the coupling is offset or angular deviation.
Pre alignment
1. Ensure that all preventive measures are taken to prevent the machine from accidentally starting. Lock/tag all machines before use.
2. Check if the equipment has gaskets and prepare if the gasket size is sufficient
3. Check if the shaft tolerance is still within a reasonable range and if there is no serious wear and tear
4. Check the gap between the couplings to ensure that there are no looseness or other abnormalities in the couplings
5. Check the stress of the load equipment pipeline to ensure that there are no abnormal loads such as deformation at all locations
6. Check the tightness between the various connecting parts of the equipment to ensure that there is no looseness.
7. Check that there is no soft foot phenomenon on the feet of the mobile device, and that the four feet are basically at the same level

Electric motor water pump laser alignment instrument, domestic coupling alignment instrument, in stockInstall measurement unit
1. Fix the measuring unit with the "S" mark in the 12 o'clock direction to the fixed mechanical side.
2. Fix the measuring unit marked with "M" in the 12 o'clock direction to the movable mechanical side.
3. The bracket is a symmetrical structure that can be used interchangeably, and other fixing methods can also be selected.
4. Lock the bracket tightly and fix it firmly on the shaft.