Widely used in industries such as power, metallurgy, chemical, petroleum, petrochemicals, municipal, environmental protection, food processing, and pharmaceuticals, with high accuracy levels up to 0.2. The measurement repeatability is good, with a maximum repeatability of 0.03%. The caliber of $r $n • covers a wide range, DN6~DN2000。 Almost no pressure loss and no flow blocking components. $r $n • Corrosion resistant, capable of testing the vast majority of corrosive conductive liquids. Multiple signal outputs, equivalent, frequency, current, and RS485 communication interface, with bus protocols such as HART, PROFIBUS, FF, and GPR
Product Overview
LDG integrated (split) typeElectromagnetic FlowmeterIt is an instrument that measures the volumetric flow rate of conductive liquids based on Faraday's law of electromagnetic induction, and is a product that combines fluid mechanics and electromagnetics. When a conductive liquid cuts magnetic field lines in a magnetic field, it generates induced electromotive force at both ends.
LDG integrated (split) typeElectromagnetic FlowmeterIt consists of two main parts: flow sensor and converter. The measuring tube is equipped with excitation coils on top and bottom, and the magnetic field generated by the excitation current passes through the measuring tube. A pair of signal electrodes are installed on the inner wall of the measuring tube in contact with the liquid, generating induced potential and transmitting the flow signal to the converter.
This seriesElectromagnetic FlowmeterIt is in the LDG seriesElectromagnetic FlowmeterA new model updated on the basisElectromagnetic FlowmeterNew breakthroughs have been made in both appearance and assembly methods, as well as in internal structure, ensuring high precision, stability, and consistency of the product. Widely used in industries such as power, metallurgy, chemical, petroleum, petrochemicals, municipal, environmental protection, food processing, and pharmaceuticals.
Product Features
High accuracy level, up to 0.2.
Good measurement repeatability, with a maximum repeatability of 0.03%.
The caliber covers a wide range, DN6~DN2000。
Almost no pressure loss, no flow blocking components.
Corrosion resistant, capable of testing the vast majority of corrosive conductive liquids.
Multiple signal outputs, equivalent, frequency, current, and RS485 communication interfaces, with optional bus protocols such as HART, PROFIBUS, FF, and wireless communication methods such as GPRS, NB, 4G.
Technical Specifications
Execution standards |
Electromagnetic Flowmeter(JB/T 9248-2015) |
Nominal meridian (mm) (special specifications can be customized) |
Threaded connection type, external threaded connection, DN15~DN50 |
Flange connection type, flange docking, DN4~DN2000 |
Clamp connection type, clamp connection, DN15~DN100 |
flow measurement |
Forward traffic, reverse traffic |
Repetitive error |
Exceeding 1/3 of the maximum allowable absolute error of the accuracy level |
Accuracy level |
0.2,0.5,1.0 |
Lining temperature resistance |
PTFE/PFA: -30 ° C~+150 ° C, split type; -30 ° C~+80 ° C, integrated type |
F46: -30 ° C~+100 ° C, split type; -30 ℃~+80 ℃, integrated type |
Chloroprene rubber: -15 ℃~+60 ° C |
Polyurethane: -15 ° C~+60 ° C |
Flow velocity range |
0.1-10m/s |
Conductivity range |
The conductivity of the measured fluid is ≥ 5 μ s/cm |
signal output |
Equivalent or frequency, 4-20mA |
Communication output |
RS485, HART, NB IoT or 4G, etc |
Power supply |
DC24V (9V~36V), AC220V (90V~250V) or lithium battery 3.6V |
Require the length of the straight pipe section |
Upstream ≥ 5DN, downstream ≥ 2DN |
Cable entrance |
Standard: M20x1.5 (6mm~10mm); Explosion proof type: M20x1.5 (6mm~10mm) |
Protection level |
IP65, Customized up to IP68 |
Environmental temperature |
-20℃~+55℃ |
Relative humidity |
5%~95% |
Explosion proof grade |
Not explosion-proof or explosion-proof (ExdibqlBCT6 Gb) |