Product Introduction
This is a reinforced version of an improved traditional planar electrode with automatic cleaning function. Due to the installation of quick release typeBNCThe joint facilitates the installation and maintenance of electrodes. Double junction reference design filled with gel inside the electrode body is adopted. This design can provide additional barrier protection against reference side contamination and allow the electrode to be used in harsh application environments, extending the electrode's lifespan.pHThe responsive flat glass surface is placed at the center of the measurement surface, surrounded by flat porous plastic reference connections, which can form good sample contacts. The version with amplified signal is used for long-distance connections, and the metal pins are used to ground the liquid. OfferCan also provideInstalling attachments allows for online, immersion, or hot swappable installation.

application
•water and wastewater treatment
•Pre chlorination and dechlorination
•Neutralization system
•Water quality monitoring
•Ozone treatment
•cooling tower
•Boiler system
•Bleach production
•Pulp bleaching
•aquaculture
•Fruit and vegetable cleaning
•Textile dyeing process
technical data
general rule
•Scope of operation:
- pHElectrode:0-14pH(None)Na+When there is an error, it is0-12.3pH)
- ORPElectrode:± 2000 mV
•Pipeline size range:DN15 - DN100(0.5” - 4”)
•New electrode performance zero voltage point:7.00pH ± 0.2pH
•New electrode performance efficiency:> 97% @ 25°C (77°F)
•New electrode performance response time:
- pH:95%The signal has been changed to<6second
- ORP: depends on the application
•reference
-Type: Sealed Double Knot
-Electrolyte: solidified gel3.5M KCl 0.1M KCl(LCElectrode version/Cured gelKCl 3.5M)
-Secondary Connection: Nylon Fiber
-Wire:Ag/AgCl.
•Process connection:
-in-line,Thread Joint”、¾”
FLSInstall accessories
-Immersion installation
-Hot swappable installation
•Working pressure/Operating temperature:
-≤6.7bar@75 °C ( 100psi@170 °F)
-≤5.7bar@81 °C ( 85psi@180 °F)
•Welding materials:
-noumenon:C-PVC(Provided only upon request)PVDF)
-Reference connection: porousHDPE
-Sensing surface: glass film(pH)Platinum glass sealing surface(ORP)
• OCircle:FPM (VITON)