E-mail
njquanju@126.com
-
Phone
13951611608
-
Address
No. 11 Shengtai Road, Jiangning Development Zone, Nanjing City
Nanjing Quanju Automation Equipment Co., Ltd
njquanju@126.com
13951611608
No. 11 Shengtai Road, Jiangning Development Zone, Nanjing City

Product Introduction
Compact FIP ULFUltra low flow sensorUsed to measure corrosive, particle free liquidsinternet traffic.1/4The inch external thread joint can be connected to hard or soft pipes.ULFCapable of following the flowfastGenerate a frequency signal proportional to the measured flow velocity for easy transmission and processing.ULFThe measurement range is divided into1.5-250L/h.Has sufficient strength and corrosion resistance.
application
•water treatment
•chemical industry
•Pharmaceutical industry
•Dosage system
•Laboratory Unit
Main characteristics
• POMperhapsECTFE(Halar ®)Liquid receiving components
•There are two traffic ranges to choose from:
- 1.5-100l/h(0.0066-0.44gpm)
- 6 - 250 l/h (0.0264 - 1.1 gpm)
•havecompareHigh chemical resistance and corrosion resistance
•Easy installation
technical data
general rule
•Flow rate range:
- ULF01edition:1.5 - 100l/h(0.0066 - 0.44gpm)
- ULF03edition:6 - 250 l/h(0.0264 - 1.1gpm)
•Linear: Full scale±1 %
•Repeatability: Full scale±0.5 %
•Working temperature:-10°C - 80°C(14°F - 176°F)
•working pressure:5 bar (70 psi) max @ 22°C (72°F)
•Liquid viscosity:1to10 cST
•Welding materials:
- POMedition:
Sensor body:POM
OCircle:FPM
Rotor:POM
Axis: Core Point
Magnet:SmCo5
- ECTFEedition:
Sensor body:ECTFE(Halar ®)
OCircle:FPMperhapsKALREZ
Rotor:ECTFE (Halar ®)
Axis: Sapphire
Bearing: Sapphire
•Connector:1/4”GASmale joint
•Cable length:2 m (6.5 ft)
ULF01.H IandULF03.H
•Power supply voltage:5 - 24 VDC ±10%(Voltage stabilization)
•Power supply current:< 15 mA @ 24 VDC
•Output signal: Square wave
•Signal type: push-pull (used to connect to)NPNandPNPInput terminal)
• K-Coefficient:
- ULF01edition:8431pulse/Ascending(31569pulse/American gallon, linear range8 - 100l/hwithin
- ULF03edition:3394pulse/Ascending(12846pulse/American gallon, linear range15 - 250 l/hwithin
ULF01.R IandULF03.R
•Power supply voltage: none
•Output signal: Square wave
•Output type: Reed contact
• K-Coefficient:
- ULF01edition:2108pulse/Ascending(7978pulse/American gallon, linear range8 - 100l/hwithin
- ULF03edition:848pulse/Ascending(3210pulse/American gallon, linear range15 - 250 l/hwithin
FIP ULFUltra low flow sensor probe modelULF01.H.0; ULF01.H.2; ULF01.H.3; ULF01.R.0; ULF01.R.2; ULF01.R.3; ULF03.H.0; ULF03.H.2; ULF03.H.3; ULF03.R.0; ULF03.R.2; ULF03.R.3.