FLUKE Ti40 Fluke thermal imager
FLUKE Ti40 Fluke thermal imager
¥ 11XXXX.0 per set
Fluke IR-Fusion ™ The technology (applied to FT series products) can combine visible images in the real world with thermal images, and it can fuse these two images into one image, including mixing them together or creating a picture in picture combination By monitoring the alarm limit through visible light images, components that exceed the set temperature range can be accurately identified Visible light images and thermal images can be used simultaneously in the report to accelerate the file generation process without the need to search for individual images captured by separate digital cameras IR Fusion can help you better identify and report suspicious components, allowing you to complete repair work in * * time
Large size * * thermal image
Due to the use of the largest display screen (5 inches) and low-noise VOx sensor among similar thermal imaging products, the Fluke IR FlexCam unit can generate high-quality images with exceptional quality, even the smallest temperature difference cannot escape its eyes The image generated by it is no less impressive than those extremely expensive instruments
Can provide * * clear images in any situation
**The movable 180 ° lens can view and capture images of areas that are difficult for personnel to enter Even on very high objects/under machines or near immovable obstacles, the display remains clear and visible Using the SmartFocus wheel can simplify the process of capturing stable and clear images, without the need to adjust the aperture while using it
Expose anomalies to the fullest
Due to the use of AutoCapture and other features, the IR FlexCam thermal imager can help you find very difficult problems The instrument is easy to set up and can automatically capture images of objects that exceed the temperature setting range, and only capture such images This way, you can focus only on the images with anomalies, helping you quickly capture and analyze intermittent issues
Adopting standard analysis and report generation methods
SmartView ™ The software (provided with the instrument) includes rich infrared image viewing/analysis/annotation and report generation tools, which even allow for customized design of reports to meet specific company programs and needs, such as multi image report generation and comparison For more information, please select the SmartView option in the content navigation on one side of this page
Radiation measurement - 'Discovering data through images'
This full radiation measurement thermal imager can capture and save thousands of matrix point calibration temperature data that make up thermal images, and can perform detailed analysis. It can also change key parameters such as emissivity or temperature range on-site through a camera or in the office through PC software
FLUKE TI40 thermal imager technical specifications
| Imaging performance |
| Hot image |
|
| Field of View (FOV) * |
23 º horizontal x 17 º vertical |
| Temperature resolution |
0.1℃ |
| *Small focusing distance * |
0.15 m |
| Thermal sensitivity (NETD) |
Ti45: ≤0.08 °C @30 °C Ti40: ≤0.09 °C @ 30 °C |
| Detector data acquisition/graphic frequency |
60 Hz/30 Hz |
| focus |
SmartFocus; Continuous focusing operation can be performed with one finger |
| IR digital zoom |
Ti45: 2x |
| |
Ti40: - |
| detector type |
160 x 120 focal plane array, vanadium oxide (VOx) uncooled microcalorimeter |
| Spectral band |
8 µm ~ 14 µm |
| Digital image enhancement |
Automatic full-time enhancement |
| Visible light (* * for Fusion models) |
|
| Camera operation mode itself |
Ti45: Full thermal/full visible light or thermal visible light mixed image picture-in-picture |
| |
Ti40: Full heat/full visible light SmartView software can provide mixed heat visible light images picture-in-picture |
| Visible light camera |
1280 x 1024 pixels, full-color |
| Visible light digital zoom |
Ti45: 2x |
| |
Ti40: - |
|
| temperature measurement |
| Calibration temperature range |
Ti45: -20 ˚C ~ 600 ˚C (-4 ~ 1112 ºF),3 档 Ti40: -20 ˚C ~ 350 ˚C (-4 ~ 662 ºF),2 档 |
| Range 1 |
Ti45: -20 ˚C ~ 100 ˚C (-4 ~ 212 ºF) |
| |
Ti40: -20 ˚C ~ 100 ˚C (-4 ~ 212 ºF) |
| Range 2 |
Ti45: -20 ˚C ~ 350 ˚C (-4 ~ 662 ºF) |
| |
Ti40: -20 ˚C ~ 350 ˚C (-4 ~ 662 ºF) |
| Range 3 |
Ti45: 250 ˚C ~ 600 ˚C (32 ~ 662 ºF) |
| |
Ti40: - |
| Optional - High Temperature |
Ti45: * Height 1200 ° C (2192 ° F) Ti40: - |
| Range 4 |
Ti45: 500 ˚C ~ 1200 ˚C (932 ~ 2192 ºF) |
| |
Ti40: - |
| accuracy |
± 2 ° C or 2% (whichever is greater) |
| Measurement Mode |
Ti45: Center point, center box (area * small/* large, average), movable point/light box, user set area/text annotation, isotherm, automatic hot/cold spot detection, visible color alarm upper and lower limits |
| |
Ti40: Center point, center box (area * small/* large, average), please consult Fluke for more upgrade options |
| Emissivity correction |
0.1~1.0 (0.01 increments) |
|
| image display |
| digital display |
5 "large screen high-resolution digital display screen |
| LCD backlight |
Color LCD, capable of reading under sunlight |
| video output |
RS170 EIA/NTSC or CCIR/PAL composite video |
| color swatch |
Grayscale, Reverse Grayscale, Blue Red, High Contrast, Hot Metallic, Iron Rainbow, Amber, Reverse Amber |
|
| Optional lenses |
| 54mm Telephoto lens |
High precision Germanium lens |
| Viewing angle (FOV) |
9 º horizontal x 6 º vertical |
| Spatial Resolution (IFOV) |
0.94 mrad |
| *Small focusing distance * |
0.6 m |
| 10.5mm wide-angle lens |
High resolution Germanium lens |
| Viewing angle (FOV) |
42 º horizontal x 32 º vertical |
| Temperature resolution |
0.1℃ |
| *Small focal distance |
0.3 m |
|
| Image and data storage |
| storage medium |
Small flash card can store over 1000 IR images (512 MB standard card, higher capacity available for selection) |
| Supported file formats |
Including 14 bit measurement data Can export JPEG, BMP, PCX, PNG, PSD |
|
| Interface and software |
| interface |
Including small flashcards * * * |
| software |
SmartView; Including all analysis and report making software |
|
| Laser (* * for IR Fusion model) |
| classification |
Level II |
| Laser aiming |
When heat and visible light images are mixed, laser dots can be seen on the screen |
|
| Control and Adjustment |
| Set Control |
Date/Time, Temperature Unit C/F, Language, Scale, LCD Brightness (High/Medium/Low) |
| Image control |
Level, span, Automatic adjustment (continuous/manual) |
| Screen indicator |
Battery status, target emissivity, background temperature, and real-time clock |
|
| power supply |
| Battery Type |
Intelligent lithium battery, rechargeable, can be replaced on site |
| Battery usage time |
Continuous use for 3 hours (2 hours for models with IR Fusion) |
| battery charging |
2 smart chargers that charge through commonly used AC sockets |
| AC operation |
AC converter 110/220 VAC, 50/60 Hz (* * on Ti45) |
| Energy saving design |
Automatic shutdown and sleep mode (users can set it themselves) |
|
| Environmental and Mechanical Design |
| Operating Temperature |
-20℃to +50℃(-4°F to 122 °F) |
| storage temperature |
-40 °C ~ +70 °C (-40 °F ~ 158 °F) |
| relative humidity |
Use and storage at 10%~95%, no condensation |
| Waterproof and dustproof |
IP54 |
| Weight (including battery) |
1.95 kg (4.3 lbs) |
| Camera size (HxWxD) |
162 x 262 x 101 mm (6.5" x 10.5" x 4.0") |
|
| other |
|
FLUKE TI40 Thermal Imaging Camera Configuration Instructions
| Model Name |
description |
| Fluke Ti40-20 |
IR FlexCam thermal imager All models come with:
- Durable and sturdy tool kit
- 2 sets of rechargeable batteries
- battery charger
- AC converter (* * for Ti45 model)
- Video cable
- 512 MB flash card, providing more choices
- Small flash card * * * and USB cable
- PCMCIA Mini Flash Card***
- suspenders
- SmartView Report Creation and Analysis Software CD
- User Manual CD
|
|
| Fluke Ti40FT-20 |
IR FlexCam thermal imager and IR Fusion |
| Fluke Ti45-20 |
IR FlexCam thermal imager |
| Fluke Ti45FT-20 |
IR FlexCam thermal imager and IR Fusion |
| option |
| Use the one on the leftConfiguratorKey to view all |
| lens |
The Ti4X series offers 10.5mm, 20mm, and 54mm lenses, and use the Configurator to see how to combine them |
| IR-Fusion |
Each model in the Ti4X series includes a 20mm lens and IR Fusion technology |
| high temperature |
Some models of Ti4X may include temperature options, with readings up to 1200 ° C (2192 ° F) |