E-mail
sales@omgl.com.cn
-
Phone
18688887615
-
Address
Room 903, 9th Floor, East Tower, Tianyu Plaza, 625 Tianhe Road, Tianhe District, Guangzhou City
Guangzhou Oumaizhi Sensing Technology Co., Ltd
sales@omgl.com.cn
18688887615
Room 903, 9th Floor, East Tower, Tianyu Plaza, 625 Tianhe Road, Tianhe District, Guangzhou City
Fast dynamic response frequency
Sturdy cable outlet connector
Low deformation
17-4 Stainless Steel Structure
Multiple range and inner diameter sizes to choose from
Bolt pre tightening force test
Force and torque measurement of electric nut wrench
LTH300 is a hollow type force sensor designed for applications such as press or axial pressure testing. The standard model LTH300 force sensor is made of 17-4 stainless steel, which is sturdy and durable. Its inner diameter can be selected between 3.18 and 9.52mm. The cable is a 3-meter-long 29 AWG 4-core PTFE shielded cable. You can also choose the corresponding sensor signal output interface according to your requirements.
FUTEK's LTH series hollow force sensors have the characteristics of high accuracy and good stiffness. Its linearity is ± 0.5%, deformation is 0.05mm, and the working temperature ranges from -50 to 93 ° C. This standard LTH300 force sensor can be customized according to your requirements, and our inventory covers most of the range and can be shipped within 24 hours. Like other force sensors, LTH300 is produced in the United States and uses metal foil strain gauge technology.
Product Specifications |
|||||
performance |
|||||
range |
222,445,1112,2224,4448 N |
||||
nonlinear |
±0.5% of RO |
||||
Hysteresis |
±0.5% of RO |
||||
non-repeatability |
±0.5% of RO |
||||
electrical | |||||
rated output |
2 mV/V |
||||
motivate |
18 (VDC or VAC) |
||||
Bridge resistance |
700 Ohm nom |
||||
insulation resistance |
≥500 MOhm @ 50 VDC |
||||
cable |
#34 AWG 4-core braided shielded silicone rubber cable, 3 meters long |
||||
mechanical | |||||
weight |
57 g |
||||
overload protection |
150% of RO |
||||
material |
stainless steel |
||||
Protection level |
IP64 |
||||
Operating Temperature | |||||
Operating temperature |
-50 to 93 ℃ |
||||
compensation temperature |
15 to 72 ℃ |
||||
Temperature drift zero point |
0.005% of RO/°C |
||||
Temperature drift range |
0.005% of Load/°C |
||||
calibration | |||||
Calibration voltage |
10 VDC |
||||
Calibration (standard) |
5 o'clock pressure direction |
||||