Overview

Introduction: Mainly used in low-pressure, room temperature, and large explosion-proof working environments such as dust collectors, dust removal pipelines, and elevators. Widely used in processing industries that generate dust, such as coal, mineral powder, medicine, fertilizers, plastics, grains, pigments, fibers, textiles, furniture, etc., to protect storage warehouses, silos, dust collectors, airflow conveying equipment, dryers and other equipment.

Product Details

In recent years, with the development of China's industry and the increasing awareness of safety, people have adhered to the policy of safety production, and provided enterprise efficiency as the ultimate goal. Safety supervision departments in various regions have increased their inspection efforts on enterprise safety, including monthly, quarterly, annual, and random inspections. They have also rectified and dealt with safety hazards that exist in enterprises. Those who fail to comply with the requirements have been shut down and sealed off. In order to solve safety hazards for enterprises and bring efficient operations. Many companies have also made corresponding rectifications based on their own situation. How can they meet the relevant requirements after rectification? The enterprise itself is still not at ease. In response to these situations, our company has conducted safety assessments based on the on-site conditions of each enterprise and designed a set of safety and economic rectification plans. Our company provides one-stop services from on-site design, product sales, on-site renovation and installation, as well as inspection and acceptance, to thoroughly solve safety hazards for enterprises and build the lowest line of defense for safety production.

  Scope of application of explosion-proof valves for dust removal equipment in factories

Mainly used in working environments with low pressure, room temperature, and large explosion-proof surfaces, such as dust collectors, dust removal pipelines, and elevators. Widely used in processing industries that generate dust, such as coal, mineral powder, medicine, fertilizers, plastics, grains, pigments, fibers, textiles, furniture, etc., to protect storage warehouses, silos, dust collectors, airflow conveying equipment, dryers and other equipment.

  Explosion proof valve

When gas or dust flows through the exhaust duct, the dust explosion-proof door valve opens; When the fan or system stops running, the dust explosion-proof valve cover plate is in the "stop" position; When the dust collector or other filter body explodes, due to the explosion airflow wave, the flow velocity of the conveying pipeline decreases, and the dust explosion-proof valve automatically closes under the action of the reverse explosion airflow, isolating the pipeline. The pressure generated by the explosion makes the isolation valve tightly adhere to the isolation end face, thereby preventing the explosion from spreading to the upstream pipeline and equipment, and playing an isolation role. This product complies with the standard EN16447 and has been certified by authoritative domestic departments.

除尘设备装置:隔爆阀
▲ Schematic diagram of explosion-proof valve

Explosion proof valve - dust explosion-proof treatment plan:

  1、 Installation method

Firstly, remove the heavy hammer from the explosion-proof valve body and tighten it in the corresponding position.

1. Confirm whether the dust characteristics transported by the pipeline can meet the construction standards before pipeline installation;

When installing explosion-proof valves, the operation of factory equipment must be stopped to ensure installation in a non potentially explosive environment;

3. Check that there are no debris inside the explosion-proof valve and pipeline;


▲ Installation method of explosion-proof valve

4. The explosion-proof valve should be supported separately and should not rely on paired pipelines for support (if not supported separately, it may affect the performance of the explosion-proof valve).

5. Dust explosion-proof valves with specifications consistent with the pipeline size should be selected;

Before installing this valve, check the cover plate to ensure that it can be flipped freely and its position is in place;

7. When installing this valve, personal protective equipment, professional clothing, and shoes should be worn. The installation personnel should use tools to eliminate sparks, ensure that the valve body is in a horizontal position, and the connection between both ends and the pipeline should be tightly sealed;

8. During debugging, it should be ensured that the cover plate is opened at least 30 degrees, and the cover plate can automatically stop at the "stop" position when the dust collector stops running

9. The installation position should not be less than the required installation distance.

除尘器隔爆阀安装案例
▲ Dust collector explosion-proof valve installation case

  2、 Power on inspection and periodic maintenance

1. Inspection work before the first startup operation:

2. Check if the explosion-proof valve flap can move freely;

3. Check if the grounding terminal is connected;

4. Check if the pipeline connections are intact;

5. Check if the installation direction of the explosion-proof valve is correct;

6. Check if the explosion-proof valve support is secure.

除粉尘设备-隔爆阀
▲ Dust removal equipment - explosion-proof valve

  pay attention toWhen starting any inspection or troubleshooting of explosion-proof valves, the protected equipment must be in a pressure free state. There should be no explosive, toxic or other harmful substances inside the equipment.

The service life of explosion-proof valves usually depends on the environment of the user's factory, and visual inspection of the overall valve and components cannot fully determine the condition of the instrument.

Every month, the explosion-proof valve should be visually inspected to identify corrosion, rupture, or deformation that may affect its normal function. Additionally, check if the gasket seal is intact and if all screws and connectors are still securely fastened.

7. The product should be shut down for inspection and maintenance at least once a month, and the inspection scope includes:

A. Sealing performance of valves

B. Tightness of valve bearing sleeve locking

2. The product undergoes annual maintenance and reliability calibration of its overall performance.

business scopeSuzhou Xinlun Hua specializes in the research and development, production, and sales of explosion-proof electrical equipment such as explosion-proof air conditioners, explosion-proof dehumidifiers, and explosion-proof containers. We offer direct sales from manufacturers and support customization! Provide services such as installation and rectification of explosion-proof circuits, explosion-proof electrical testing and maintenance!