Name: Fat content detection centrifuge
model:Lacter 21
Origin: Spain
Application:Maximum capacity12 butyrometersMaximum speed224 xg/1,200 RPM
Product Introduction:
The centrifuge is designed for use according toGerberMethod for determining dairy products (cheese, milk, yogurt)......)Medium fat.
Function:
l Heating: Working temperature up to80 ° C(176 ° F).
l LCD screen:
l RPMandFCRIndicators, time, temperature, and acceleration/Braking(PCBS).
l Programmable speed, with a stride of50 RPM / 50 xg.
l count backwards/follow0perhaps“settingRPM / FCR”Rise to obtain reproducible results.
l Clock from1arrive99Minutes, programmable interval5Second, and able to maintain position.
l PCBSProgressive controllable acceleration and braking system, maximum175An optional ramp can prevent homogenization of the separated sample.
l 16A programmable memory.
l The sound and visual information on the screen display the status of the device to the user.
Easy to operate:
l Controlled by a microprocessor.
l Maintenance free induction motor (brushless).
l List of rotors in memory.
l Noise level: less than60Decibel.
l The button is used for starting, stopping, lid opening, and short cycles with adjustable speed.
l Can be prevented during operation/modifyRPM / FCR.
l The final parameters are saved in memory.
l Automatically identify the rotor. Prevent speeding.
Safety:
l Provide the cover of the security system:
-Automatic shutdown, dual anchorage maneuvering. Manual emergency activation.
-Block and prevent opening during operation.
-Prevent the lid from falling off.
-The viewfinder is used for calibration and operational checks.
l Unbalanced system with automatic stop.
l The protective safety ring between the centrifuge chamber and the outside of the equipment.
l Stainless steel centrifuge chamber (easy to clean).
l The rotor and reducer that can be sterilized under high pressure are easy for users to install.
l Automatic disconnection, energy-saving up to8Hours, can be optionally deactivated.
District regulations and directives:
Community directive:2011/65 / EU,2012/19 / EU,2014/30 / EU,2014/35 / EU,98/79 / EC.
Standard:EN 61010-1,EN 61010-2-020,EN 61326-2-6,EN 61326-1,EN 61010-2-010.
edition:
|
code |
Size(mm)(axlxh) |
Net weight(kg) |
Voltage(v) |
Frequency(Hz) |
Consumption(w) |
heating |
||
|
CE 158 |
365 |
300 |
450 |
23 |
220-230 |
50 |
500 |
SI |
|
CE 159 |
365 |
300 |
450 |
23 |
110-120 |
50 |
480 |
SI |