1、 Product Description:
IDG100-D-F2Fixed fluorine gas detector alarmIn terms of design, a large screen display is adopted, and all parameters are intuitive and clear. The gas concentration is displayed with a 50 segment bar chart, allowing observers to easily understand the percentage of gas concentration. In terms of parameter settings, equipped with an infrared remote control, customers can complete the machine settings without opening the cover. The instrument backlight adopts dual color backlight. Once the gas concentration exceeds the standard on site, in addition to turning on the sound and light alarm, the red backlight of the instrument lights up, and the large screen displays the alarm level, conveying the alarm information to the on-site personnel.
Fluorine gasdetectorAlso known as:Fluorine gasAlarm systemFluorine gasTransmitterFluorine gasProbe with displayFluorine gasDetectorFluorine gasTesting equipmentFluorine gasanalyzerWait. The gas sampling methods are divided into diffusion type, pump suction type, and pipeline type, and customers can choose the sampling method according to their actual application. The instrument is powered by DC24V, and the output signals include 4-20mA, 0-5V, RS485, wireless signals, etc. The output signals can be combined with Weilian An IDG1000D control alarm, PLC, DCS and other control systems to complete online real-time monitoring, alarm control, fan control, solenoid valve control and other functions.
2、 Product Features:
Adopting explosion-proof design, the explosion-proof mark is Exd Ⅱ CT6 Gb
Using high-speed and high-precision processing circuits to process sensor signals, the response speed is fast, the measurement accuracy is high, and the stability and repeatability are good
Large screen display, visually displaying information such as gas concentration, type, unit, range, concentration column status chart, etc
Using the arrow menu, various operations such as zero adjustment, calibration, low alarm, high alarm, reset, etc. are intuitive and clear
Can be equipped with remote control operation, no need to open the cover, simple operation
More comprehensive alarm information: LCD alarm level display, LCD red backlight on, sound and light alarm on (optional)
The independent design of the gas chamber, combined with aerodynamics, enables faster and more accurate detection of target gases
Full range temperature digital automatic tracking compensation ensures measurement accuracy
Equipped with data recovery function, there is no need to worry about misoperation
RS485、 Three wire system 4-20mA, 0-5V output, relay output and optional sound and light alarm
We can provide customers with WLO Sin gas collection software, which has real-time display, storage, query, and export functions
3、 Application scenarios
Petroleum and petrochemical, metallurgy, environmental monitoring, paper printing and dyeing, chemical plants, pharmaceutical plants, * * plants, garbage treatment plants, sewage treatment plants, fire alarms, scientific research and education, power and telecommunications, ships, etc
4、 Technical parameters
|
gas detection |
Fluorine gasF2 |
||
|
Detection Principle |
electrochemistry |
||
|
Detection range |
0-1, 5, 10ppm(For other ranges, please consult) |
||
|
resolution |
0.01The0.1ppm |
||
|
design standards |
GB50493-2009Design Specification for Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Enterprises GB 12358-2006General Technical Requirements for Workplace Gas Detection and Alarm Devices |
||
|
execution standard |
GB3836.1-2010Electrical equipment for explosive gas environments Part: General requirements GB3836.2-2010Electrical equipment for explosive gas environments * * Part: Explosion proof type“d”》 Q/WLA 001-2015Enterprise Execution Standards of Shenzhen Weilian'an Technology Co., Ltd |
||
|
Working Voltage |
DC24V±6V |
operating current |
<100mA |
|
Shell material |
aluminum alloy |
display mode |
LCDdisplay |
|
Detection method |
Diffusion type, pump suction type, pipeline type |
Installation method |
Wall mounted, pipe mounted, and pole mounted |
|
detection accuracy |
±3% |
repeatability accuracy |
±3% |
|
response time |
<30S |
linearity |
±2% |
|
zero drift |
±1%F.S/year |
signal output |
RS485The4-20mA(For other signals, please consult) |
|
work pressure |
85~105KPa |
product lifespan |
2~5year |
|
Operating Temperature |
-20~50℃ (please consult for special requirements) |
Operating Humidity |
10~95%RHNon condensing |
|
audible and visual alarm |
redLEDThe85db@1mBuzzer (optional) |
relay |
3A@DC24V(Optional) |
|
Explosion-proof rating |
ExdⅡCT6 Gb |
Protection level |
IP65 |
|
Wiring thread |
M20*1.5internal thread |
Wiring wires |
RVVP 3*0.75mm2 |
|
Overall dimensions |
125*106*153mm |
Total weight |
1.8Kg |
|
Appendix document |
Packaging box, instruction manual, certificate of conformity |
||