Fixed six in one gas alarm, gas detector, multi gas detection, simultaneous detection of toxic and flammable substances, and simultaneous detection of toxic and flammable substances, GTQ-YA-C100, 1 machine, 6 tests: simultaneous detection of 4 gases, temperature, and humidity, real-time display of concentration parameters, supporting customization. LoRa wireless communication, infrared remote control, and cloud platform management system.
















Fixed six in one gas alarm
GTQ-YA-C100, 1 machine, 6 tests: simultaneous detection of 4 gases, temperature, and humidity, real-time display of concentration parameters, supporting customization. LoRa wireless communication, infrared remote control, and cloud platform management system.
The GTQ-YA-C100 series all-in-one gas detector is widely used in hazardous indoor and outdoor environments where toxic and flammable gases are generated, stored, and used, such as chemical, petroleum, metallurgical, liquefied gas stations, painting operations, gas transmission and distribution. The GTQ-YA-C100 series all-in-one gas detector is a functional and easy-to-use gas detector developed by our company. Can be combined with our YA-K series gas alarm controller to form an industrial gas alarm system.
This product is installed in a wall mounted (or pipe mounted, bracket mounted, suspended ceiling mounted) manner, and is used in conjunction with a controller to process various data uploaded by the gas detector through the microcontroller of the controller, ultimately achieving functions such as data display and output control.
It is strictly prohibited to dismantle it casually. 2. It is strictly prohibited to immerse gas detectors in liquids such as water and oil, or install them in places with corrosive gases. 3. It is strictly prohibited to use a large amount of gas directly towards the gas detector to avoid sensitivity reduction or damage to the sensor. 4. Gas detectors should be calibrated at least once a year to ensure detection accuracy. 5. The probe is prohibited from pure gas testing, and it is strictly forbidden to use a lighter for fumigation testing to avoid premature failure of the gas detector due to excessive concentration of gas fumigation testing.
Fixed six in one gas alarm
Supports sound and light output. ☆ Zero adjustment, calibration, and testing functions. ☆ Supports 485, dual bus LoRa, Flexible and versatile communication methods. Equipped with high-performance ARM microprocessors that are easy to operate. ☆ One relay (250V5A) output, automatically turns on the fan. Toxic gases can be converted between mg/m3 and μ mol/mol.