Welcome Customer !

Membership

Help

Jinan Micro Nano Particle Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Jinan Micro Nano Particle Instrument Co., Ltd

  • E-mail

    Wnmarket@126.com

  • Phone

    15553132835

  • Address

    Building F, North Campus, University Science and Technology Park, High tech Zone, Jinan City

Contact Now

Fully automatic wet particle size analyzer

NegotiableUpdate on 12/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The fully automatic wet particle size analyzer Winner2000ZD adopts a directional scattered light detection system, combined with a high-sensitivity ring photodetector, to further improve the testing accuracy. The dispersion system that integrates mechanical stirring, ultrasonic dispersion, and built-in circulation solves the problem of large particles depositing in pipelines.
Product Details

Fully automatic wet particle size analyzerThe Winner2000ZD instrument adopts a directional scattered light detection system, combined with a high-sensitivity ring photodetector, to further improve the testing accuracy. The dispersion system that integrates mechanical stirring, ultrasonic dispersion, and built-in circulation solves the problem of large particles depositing in pipelines. **The unconstrained free fitting software technology ensures the authenticity and accuracy of the test results. Adopting self-developed intelligent control technology, it can achieve automatic alignment of the optical path and perform one click testing.

Features:

1. Intelligent operation mode, supporting one click operation. Click on "Auto Test", follow the prompts to add the sample, and all other operations will be automatically completed. Not only does it reduce the workload of testers, but it also eliminates interference errors caused by human factors.

2. The optical path automatic centering system is composed of a precision four item hybrid stepper motor, with micro motion accuracy reaching the micrometer level, ensuring that the instrument's optical path is always in a * * state.

3. Adopting a fully built-in dispersion system, integrating mechanical stirring, ultrasonic dispersion, and pipeline circulation, the overall control coordination is good, and the pipeline is shortened to prevent secondary sedimentation of large particles.

4. Using unconstrained free fitting techniques of micro nano * *, particle size analysis is not limited by any function and can truly reflect the distribution state of particles.

5. Advanced optical path design: Adopting micro nano specialized converging light Fourier transform optical path, effectively improving the ability to distinguish submicron particles.


Fully automatic wet particle size analyzerTechnical Specifications:

Specification Model

Winner2000ZDE

Winner2000ZD

execution standard

ISO13320:2009,GB/T19077-2016,Q/0100JWN001-2013

test scope

0.1-300μm

0.1-40μm /0.6-120μm/1-300μm

Number of detector channels

78

76×3

Accuracy error

Less than 0.5% (D50 value of national standard sample)

repeatability error

less than0.5% (D50 value of national standard sample)

Laser parameters

High performance He Ne laser with λ=632.8nm and p>2mW,Service life:>25000H

Built in dispersion method

ultrasound

Frequency: f=40KHz, power: p=60W, adjustable time

stir

Speed: 0-3000rpm, adjustable speed

cycle

Rated flow rate: 8L/min Rated power: 10W

sample pool

Capacity: 350mL

Operation Mode

Software operation/fully automatic operation mode can be switched

Central system

Fully automatic centering system

Software features

Analysis Pattern

Including free distribution, R-R distribution, lognormal distribution, and hierarchical statistical models, it meets the different requirements of different industries for the statistical methods of particle size of the tested samples

statistical method

Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

Statistical comparative analysis can be conducted on multiple test results, which can significantly compare the differences in test results between different batches of samples, samples before and after processing, and test results at different times. This has strong practical significance for industrial raw material quality control

Custom Analysis

User defined analysis parameters, calculated as percentages based on particle size, percentages based on particle size, or percentages based on particle size ranges, to meet the characterization requirements of different industries for particle size testing

Test Report

The test report can be exported in various forms such as Word, Excel, images (Bmp), and text (Text), meeting the needs of viewing test reports in any situation and citing test results in scientific research articles

Multi language support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.

Intelligent operation mode

Equipped with intelligent operation mode, it can automatically control the steps of water inlet, dispersion, testing, etc., which not only reduces the workload of testing personnel, but also improves the repeatability of test results due to no human interference.

test speed

<2min/time

volume

880mm*390mm*460mm

weight

41Kg