Test account usage

  • E-mail

    873582201112@qq.com

  • Phone

  • Address

    Hangzhou

Contact Now

GDRD59

NegotiableUpdate on 02/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
GDRD59
Product Details
Features: Multiple antennas, anti condensation, crystallization, hanging, dust, beam concentration.
Application: Used for measuring solid material levels with short measurement ranges.
Large distance: 15m
Measurement accuracy: ± 10mm
Antenna material: (T-shaped) stainless steel 316L horn/PTFE oscillator
(V-shaped) stainless steel 316L/PTFE oscillator
(W-type) stainless steel 316L/PTFE oscillator
Antenna structure: (T-shaped) conical oscillator, anti condensation material difference
(V-shaped) cone oscillator, anti condensation material
(W-shaped) parabolic antenna with a 4-degree opening angle
Process temperature: (T-type) (-40~200) ° C
(V type) (-40~200) ° C
(W-type) (-40~200) ° C
Process pressure: (T-type) (-0.1~4) MPa
(V-shaped) (-0.1~0.3) MPa
(W-type) (-0.1~4) MPa
Frequency range: 26GHz
Signal output: (4-20) mA/HART
Power supply: four wire system

Detailed introduction:
GDRD59
license
P standard type (non explosion proof)
I intrinsic safety type (Exia IIC T6)
G intrinsic safety type+explosion-proof type (Exd [ia] ia IIC T6)
Antenna type/material
K (S-type) horn antenna with a diameter of 98mm/PP and PTFE cover
L (S-type) horn antenna with a diameter of 98mm (extended)/PP/PTFE cover
X 特殊定制
Process Connection/Materials
GB (G) thread G1 half A/PP
GX 特殊定制
Flange selection/materials
HA (L) DN100 flange/PP
HD (N) DN100 universal joint flange/PP
GX 特殊定制
Sealing/process temperature
2 Viton(-60~80)℃
electronic component
B (4-20) mA/HART two-wire system
C (4-20) mA/(22.8-26.4) V DC/HART two-wire/four wire system
D (198-242) V AC/HART four wire system
Shell/protection level
Aluminum/IP67
B Plastic/IP66
D aluminum two chamber/IP67
Cable incoming line
M M20x1.5
N ½NPT
On site display/programming
A belt
X without
Note: The intrinsic safety type (Exia IIC T6) is only compatible with "B" electronic components and "A" type enclosures; Intrinsic safety+explosion-proof type (Exd [ia] ia IIC T6)
Only use "D" electronic components and "D" type casing; The standard flange size refers to GB/T9119-2000 PN1.6MPa size, with a thickness of 15