Welcome Customer !

Membership

Help

Running Industrial (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Running Industrial (Shanghai) Co., Ltd

  • E-mail

    sh@tiantian117.com

  • Phone

    18916040785

  • Address

    Room 606, Futong Dingqia Building, No. 2300 Yangshupu Road, Shanghai

Contact Now

HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy

NegotiableUpdate on 06/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy. Measurement range: 0.00 to 14.00 pH, pH mV: ± 600.0 mV, mV/ORP: ± 2000.0 mV, EC: 0 to 200 mS/cm, TDS: 0.0 to 400.0 ppt (g/L), resistivity: 0 to 1.0000 M Ω• cm, salinity: 0.00 to 70.00 PSU. Sea water specific gravity: 0.0 to 50.0 σ t, σ ₀, σ ₁ ₅ DO: 0.0 to 500.0%, 0.00 to 50.00 ppm (mg/L) Italy HANNA portable conventional water quality five parameter instrument HI98194, HANNA portable pH/conductivity/dissolved oxygen/temperature multi parameter instrument HI98194 meets IP67 international waterproof standards, with pH pH pH mV conversion oxidation-reduction ORP conductivity EC resistivity total dissolved solids TDS salinity dissolved oxygen saturated dissolved oxygen seawater specific gravity atmospheric pressure temperature and other 12 important water quality indicators measured quickly and accurately, automatically identifying range and unit conversion; New appearance design, on-screen calibration operation steps prompts, GLP function, quick query of relevant data, acidity verification function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large capacity data .....

Product Details

Hana HANNA portable conventional water quality five parameter instrument HI98194

Measurement range:0.00 to 14.00 pH、pH-mV: ± 600.0 mVmV/ORP: ± 2000.0 mVEC:0 to 200 mS/cm、

TDS:0.0 to 400.0 ppt(g/L)、resistivity: 0 to 1.0000 M Ω• cmsalinity:0.00 to 70.00 PSU
Specific gravity of seawater: 0.0 to 50.0 σ t, σ ₀, σ ₁ ₅DO:0.0 to 500.0%、0.00 to 50.00 ppm (mg/L)

Hana HANNA portable conventional water quality five parameter instrument HI98194,

Hana HANNA portable pH/conductivity/dissolved oxygen/temperature multi parameter instrument HI98194

Complies with IP67 international waterproof standards, with pH pH mV conversion oxidation-reduction ORP conductivity EC resistivity total dissolved solids TDS salinity dissolved oxygen saturated dissolved oxygen seawater specific gravity atmospheric pressure temperature and other conventional important 12 water quality indicators measured quickly and accurately, automatically identifying range and unit conversion;

New appearance design, on-screen calibration operation steps prompts, GLP function, quick query of relevant data, acidity verification function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large capacity data storage, excellent data management



TECHNICAL INDEX

HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy

Multi parameter electrode types

HI7697194pH/mV-EC/TDS-DOBuilt in temperature sensor with multi parameter electrode and long wire:4rice、10rice、20rice、40rice
【HI7697194-1 pH/mVelectrode;HI7697194-2 dissolved oxygenDOelectrode、HI7697194-3 EC/TDSelectrode】

pH-mV measuring range

0.00 to 14.00 pH, ± 600.0 mV

Resolution accuracy

0.01 pH 、0.1 mV;± 0.02 pH, ± 0.5 mV

Calibration Mode

Up to three automatic recognition calibrations and one custom calibration, with built-in standard calibration points:4.01、6.86、7.01、9.18、10.01pH
redox【ORP】
measuring range

± 2000.0 mV

Resolution accuracy

0.1 mV;± 1.0 mV

Calibration Mode

Single point custom calibration

conductivity【EC】 measuring range

0 to 200 mS/cm;Absolute/Actual Conductivity:400 mS/cm【 Turn off temperature compensation function 】

resolution

Manual selection:1 µ S/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm

Automatic selection:1 µ S/cm 【 0 to 9999 µ S/cm】、0.01mS/cm【10.00 to 99.99 mS/cm】、0.1mS/cm【100.0 to 400.0 mS/cm】
Automatic selection:0.001 mS/cm【0.000 to 9.999 mS/cm】、0.01mS/cm【10.00 to 99.99 mS/cm】、0.1mS/cm【100.0 to 400.0 mS/cm】

accuracy

reading± 1% or 1 µ S/cm,Take the largest one

Calibration Mode

Automatic recognition of single point calibration, user-defined calibration, built-in standard calibration points:84 µ S/cm, 1413 µ S/cm, 5.00mS/cm, 12.88mS/cm, 80.0mS/cm, 111.8mS/cm

TDS
【TDS】

measuring range

0.0 to 400.0 ppt(g/L)The maximum value depends onTDSConversion coefficient

resolution

Manual Selection:0.001 ppt(g/L)、0.01 ppt(g/L)、0.1 ppt(g/L)、1 ppt(g/L)

auto select:1 ppm【0 to 9999 ppm】、0.01ppt【10.00 to 99.99 ppt】、0.1ppt【100.0 to 400.0 ppt】
Automatic selection:0.0001 ppt【0.000 to 9.999 ppt】、0.01ppt【10.00 to 99.99 ppt】、0.1ppt【100.0 to 400.0 ppt】

Other indicators

Accuracy: Reading± 1% or 1 ppm (mg/L),Take the largest one; Calibration mode:No calibration required,Based on conductivity calibration
resistivity measuring range

0 to 999999 Ω• cm, 0 to 1000.0 k Ω• cm, 0 to 1.0000 M Ω• cm

Other indicators

Resolution: depends on resistivity reading, calibration mode: no calibration required, based on conductivity calibration

salinity measuring range

0.00 to 70.00 PSU

Other indicators

Resolution:0.01 PSU、Accuracy: Reading±2%perhaps 0.01 PUSTake the largest one; Calibration mode:No calibration required, based on conductivity calibration

Specific gravity of seawater measuring range

0.0 to 50.0 σt, σ₀, σ₁₅

Other indicators

resolution:0.1 σt, σ₀, σ₁₅;measurement accuracy:±1σt, σ₀, σ₁₅;Take the largest one; Calibration mode: No calibration required, based on conductivity calibration

dissolved oxygen measuring range

0.0 to 500.0%、0.00 to 50.00 ppm (mg/L)

resolution

0.01 mg/L(ppm)、0.1 %

measurement accuracy

dissolved oxygen【DO】:reading± 1.5% or 0.10 mg/L (ppm),Take the largest one【≤30.00 mg/L】;reading± 3% [>30.00mg/L]

saturated dissolved oxygen【DO%】:reading± 1.5% or 1.0%,Take the largest one【≤300.0%】,reading± 3% [>300.0%]

Calibration Mode

Single point or two-point automatic calibration and a custom calibration, zero point [recommended]HI7040】Or automatically in the air100%calibration

atmospheric pressure measuring range

450 to 850 mm Hg、17.72 to 33.46 in Hg、600.0 to 1133.2 mbar
8.702 to 16.436 psi、0.5921 to 1.1184 atm、60.00 to 113.32 kPa

resolution

0.1 mm Hg、0.01 in Hg、0.1 mbar、0.001 psi、0.0001 atm、0.01 kPa

Other indicators

Measurement accuracy:±3 mm Hg @ ±15°C;Calibration mode: Single point custom calibration

temperature measuring range

-5.00 to 55.00 ° C, 23.00 to 131.00 ° F, 268.15 to 328.15K

Other indicators

resolution:0.01 ° C, 0.01 ° F, 0.01K;accuracy± 0.15 ° C, ± 0.27 ° F, ± 0.15K(Ignoring probe errors); Calibration mode: Single point custom calibration

other temperature compensation

automatic temperature compensation -5 to 55°C (23 to 131°F)

Data Storage

45000 Record all parameters through continuous measurement or on-demand measurement】Record interval:1Seconds to3Hourly recording interval setting
USBInterface(HI9298194Data Management Transmission Software and Transmission Cable Suite

Power Mode

1.5V×4AAA Battery【4joint5SIZE AAA】

application environment

0 to 50 ° C (32 to 122 ° F), RH 100% IP67

Dimension

Host size:185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”);Weight:400 g (14.2 oz.)


HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy

Portable pH/conductivity/dissolved oxygen/temperature multiparameter HI98194


HI98194

Host, HI7698194-04 custom built-in pH EC-DO multi parameter electrode, 4 meters long, HI9828-20 rapid comprehensive calibration solution (specification: 230mL), HI7698292 specialized dissolved oxygen electrode maintenance accessory set, HI7698290 custom specialized rapid calibration measuring cup, HI9298194 custom specialized data management and transmission software, HI920015 custom specialized data transmission cable , Chinese and English user manual, HI720194 custom specialized instrument carrying case

HI98194/10

Host, HI7698194-04 custom built-in pH EC-DO multi parameter electrode, 10 meters long, HI9828-20 rapid comprehensive calibration solution (specification: 230mL), HI7698292 special dissolved oxygen electrode maintenance accessory set, HI7698290 custom special rapid calibration measuring cup, HI9298194 custom special data management transmission software, HI920015 custom special data transmission cable , Chinese and English user manual, HI720194 custom special instrument carrying case

HI98194/20

Host, HI7698194-04 custom built-in pH EC-DO multi parameter electrode, 20 meters long, HI9828-20 rapid comprehensive calibration solution (specification: 230mL), HI7698292 special dissolved oxygen electrode maintenance accessory set, HI7698290 custom special rapid calibration measuring cup, HI9298194 custom special data management transmission software, HI920015 custom special data transmission cable , Chinese and English user manual, HI720194 custom special instrument carrying case

HI98194/40

Host, HI7698194-04 custom built-in pH EC-DO multi parameter electrode, 40 meters long, HI9828-20 rapid comprehensive calibration solution (specification: 230mL), HI7698292 special dissolved oxygen electrode maintenance accessory set, HI7698290 custom special rapid calibration measuring cup, HI9298194 custom special data management transmission software, HI920015 custom special data transmission cable , Chinese and English user manual, HI720194 custom special instrument carrying case

HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy

  • Standard solution/standard group
  • HI9828-0 HI9828/1G

    Specialized acidity pH conductivity EC mixed calibration solution

    Standard value @ 25 º C: 6.86pH [acidity]&5000uScm [conductivity], specifications: 500 mL, 3700mL rapid acidity and conductivity single point rapid calibration, suitable for Hanna's HI9828 and HI9829 series multi parameter measuring instruments, ideal for environmental, wastewater treatment, water analysis, industrial, aquaculture and other field operations. Made with high-purity chemical reagents and high-quality deionized water, carefully prepared using rigorously certified measuring tools and containers in a constant temperature and humidity environment that meets requirements, and traceable to NIST standard reference materials (SRM); The Hanna brand's dedicated pH conductivity EC mixed calibration solution is formulated with a special formula and sealed with a unique tamper proof setting to ensure the quality and freshness of the dedicated pH conductivity EC mixed calibration solution. It remains unopened in a suitable storage environment and has a maximum shelf life of 5 years;