Hana HANNA portable conventional water quality five parameter instrument HI98194
Measurement range:0.00 to 14.00 pH、pH-mV: ± 600.0 mVmV/ORP: ± 2000.0 mVEC:0 to 200 mS/cm、
TDS:0.0 to 400.0 ppt(g/L)、resistivity: 0 to 1.0000 M Ω• cmsalinity:0.00 to 70.00 PSUHana HANNA portable conventional water quality five parameter instrument HI98194,
Hana HANNA portable pH/conductivity/dissolved oxygen/temperature multi parameter instrument HI98194
Complies with IP67 international waterproof standards, with pH pH mV conversion oxidation-reduction ORP conductivity EC resistivity total dissolved solids TDS salinity dissolved oxygen saturated dissolved oxygen seawater specific gravity atmospheric pressure temperature and other conventional important 12 water quality indicators measured quickly and accurately, automatically identifying range and unit conversion;
New appearance design, on-screen calibration operation steps prompts, GLP function, quick query of relevant data, acidity verification function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large capacity data storage, excellent data management
| TECHNICAL INDEX |
HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy |
|
|
Multi parameter electrode types |
HI7697194pH/mV-EC/TDS-DOBuilt in temperature sensor with multi parameter electrode and long wire:4rice、10rice、20rice、40rice |
|
| pH-mV | measuring range |
0.00 to 14.00 pH, ± 600.0 mV |
|
Resolution accuracy |
0.01 pH 、0.1 mV;± 0.02 pH, ± 0.5 mV | |
|
Calibration Mode |
Up to three automatic recognition calibrations and one custom calibration, with built-in standard calibration points:4.01、6.86、7.01、9.18、10.01pH | |
|
redox【ORP】 |
measuring range |
± 2000.0 mV |
| Resolution accuracy |
0.1 mV;± 1.0 mV |
|
| Calibration Mode |
Single point custom calibration |
|
| conductivity【EC】 | measuring range |
0 to 200 mS/cm;Absolute/Actual Conductivity:400 mS/cm【 Turn off temperature compensation function 】 |
| resolution |
Manual selection:1 µ S/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm
Automatic selection:1 µ S/cm 【 0 to 9999 µ S/cm】、0.01mS/cm【10.00 to 99.99 mS/cm】、0.1mS/cm【100.0 to 400.0 mS/cm】 |
|
| accuracy |
reading± 1% or 1 µ S/cm,Take the largest one |
|
| Calibration Mode |
Automatic recognition of single point calibration, user-defined calibration, built-in standard calibration points:84 µ S/cm, 1413 µ S/cm, 5.00mS/cm, 12.88mS/cm, 80.0mS/cm, 111.8mS/cm |
|
|
TDS |
measuring range |
0.0 to 400.0 ppt(g/L)The maximum value depends onTDSConversion coefficient |
| resolution |
Manual Selection:0.001 ppt(g/L)、0.01 ppt(g/L)、0.1 ppt(g/L)、1 ppt(g/L)
auto select:1 ppm【0 to 9999 ppm】、0.01ppt【10.00 to 99.99 ppt】、0.1ppt【100.0 to 400.0 ppt】 |
|
|
Other indicators |
Accuracy: Reading± 1% or 1 ppm (mg/L),Take the largest one; Calibration mode:No calibration required,Based on conductivity calibration | |
| resistivity | measuring range |
0 to 999999 Ω• cm, 0 to 1000.0 k Ω• cm, 0 to 1.0000 M Ω• cm |
| Other indicators |
Resolution: depends on resistivity reading, calibration mode: no calibration required, based on conductivity calibration |
|
| salinity | measuring range |
0.00 to 70.00 PSU |
| Other indicators |
Resolution:0.01 PSU、Accuracy: Reading±2%perhaps 0.01 PUSTake the largest one; Calibration mode:No calibration required, based on conductivity calibration |
|
| Specific gravity of seawater | measuring range |
0.0 to 50.0 σt, σ₀, σ₁₅ |
| Other indicators |
resolution:0.1 σt, σ₀, σ₁₅;measurement accuracy:±1σt, σ₀, σ₁₅;Take the largest one; Calibration mode: No calibration required, based on conductivity calibration |
|
| dissolved oxygen | measuring range |
0.0 to 500.0%、0.00 to 50.00 ppm (mg/L) |
| resolution |
0.01 mg/L(ppm)、0.1 % |
|
| measurement accuracy |
dissolved oxygen【DO】:reading± 1.5% or 0.10 mg/L (ppm),Take the largest one【≤30.00 mg/L】;reading± 3% [>30.00mg/L] saturated dissolved oxygen【DO%】:reading± 1.5% or 1.0%,Take the largest one【≤300.0%】,reading± 3% [>300.0%] |
|
| Calibration Mode |
Single point or two-point automatic calibration and a custom calibration, zero point [recommended]HI7040】Or automatically in the air100%calibration |
|
| atmospheric pressure |
measuring range |
450 to 850 mm Hg、17.72 to 33.46 in Hg、600.0 to 1133.2 mbar |
| resolution |
0.1 mm Hg、0.01 in Hg、0.1 mbar、0.001 psi、0.0001 atm、0.01 kPa |
|
| Other indicators |
Measurement accuracy:±3 mm Hg @ ±15°C;Calibration mode: Single point custom calibration |
|
| temperature | measuring range |
-5.00 to 55.00 ° C, 23.00 to 131.00 ° F, 268.15 to 328.15K |
| Other indicators |
resolution:0.01 ° C, 0.01 ° F, 0.01K;accuracy± 0.15 ° C, ± 0.27 ° F, ± 0.15K(Ignoring probe errors); Calibration mode: Single point custom calibration |
|
| other | temperature compensation |
automatic temperature compensation -5 to 55°C (23 to 131°F) |
| Data Storage |
45000 Record all parameters through continuous measurement or on-demand measurement】Record interval:1Seconds to3Hourly recording interval setting |
|
| Power Mode |
1.5V×4AAA Battery【4joint5SIZE AAA】 |
|
| application environment |
0 to 50 ° C (32 to 122 ° F), RH 100% IP67 |
|
| Dimension |
Host size:185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”);Weight:400 g (14.2 oz.) |
|
HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy
HANNA Hana portable conventional water quality five parameter instrument HI98194 from Italy
HI9828-0 HI9828/1G