Our company has over 20 years of experience in the development of electrical measurement and control, industrial control products, covering fields such as power, communication, intelligent buildings, intelligent transportation, energy conservation and environmental protection, oil field Internet of Things, coal mine automation, industrial automation, agriculture and environmental protection. Successful engineering cases include generator set control, mobile base station energy consumption monitoring, machine room dynamic environment monitoring, data center monitoring, remote monitoring of pumping units and other industries.
HC-1I3E-series AC current transmitter
Product Introduction
This series of productsThe measured AC current can be isolated and converted into a linear proportion
Output standard DC voltage ordirect currentCurrent signal;
It has the characteristics of high precision, high isolation, stable performance, and strong resistance.
standardDIN rail (35mm) installation, 1P (18mm) width, plug-in terminal wiring;
Technical Specifications
1. Execution standard:GB/T 13850-1998,ICE688:1992
2. Input specification: currentrange1A、5A、0~100A and other optional options
3. inputfrequency: Power frequency,45~65Hz
4. Input impedance:≤100mΩ
5. Input overload capacity:1.2 times the range is sustainable; Instantly (<10 cycles) 5 times the range without damage
6. Output specifications:Standard DC signals such as 0-20mA, 4-20mA, 0-5V, 0-10V, etc
7. Accuracy level:0-5/10V output type ± 0.2% F.S, 0/4-20mA output type ± 0.5% F.S
8. Linear range:1% to 100% nominal value
9. Output load capacity: voltage output type5mA; passive voltage output type load resistance should be greater than 10K;
Current output type≤650W(24V power supply), ≤ 200W(12V power supply)
10. Output ripple:≤ 10mV (effective value, at rated output load)
11. Response time:≤300ms
12. Pressure resistance strength: input/2000V between output/casingAC/min; 500VDCTime>100MΩ
13. Working environment: -10℃~60℃;relative humidity5~95%no condensation
14. Temperature drift:≤ 150PPM (within the range of -10 ℃ to+60 ℃)
15. Auxiliary power supply:DC12~24V
16. Current consumption:≤65mA
17. Installation method:35mmstandardDINrail mounting
18. Product dimensions:E-type: 98.6×18×66.6mm;
Appearance and installation

E-type external dimension diagram
Installation: Using35mmstandardDINInstall the guide rail, fix the guide rail, and then clip the product into the guide rail;
Wiring: Use0.2~3.3mm²The cable (input line for current should be selected to be greater than)Strip 6mm from the end of each wire (2mm ² cable) and connect it to the terminal, then insert the wire into the corresponding position of the connecting terminal. Tighten the wiring screw to a torque of 0.56-0.79N · m.
Typical wiring diagram