HD2107.1 and HD2107.2 are single channel inputs, while HD2127.1 and HD2127.2 are dual channel inputs with LCD displays for handheld thermometers that can measure temperature using immersion, insertion, contact, or air probes. Sensors can be 3-wire or 4-wire Pt100 and 2-wire Pt1000. All models of probes are equipped with intelligent detection modules, and the factory calibrated data has been stored in the modules.
HD2107.2 and HD2127.2 have data storage function, which can store up to 80000 data and transfer the data to the computer through RS232C and USB interface. Storage interval, printing, and baud rate can all be set in the menu. All models have an RS232C serial interface, which can transmit data in real-time to a computer or printer.At the same time, it can calculate the maximum, minimum, and average values, and also has relative measurement REL, display the current measurement value HOLD range, and automatic shutdown function. The automatic shutdown function can be canceled.
The protection level is IP66.
Technical Specifications:
|
model |
HD2127.1 |
HD2127.2 |
|
double rowLCDdisplay |
41/2number+Function symbol |
41/2number+Function symbol |
|
unit of measurement |
℃--℉--K |
℃--℉--K |
|
measurement |
maximum--minimum--average |
maximum--minimum--average |
|
storage |
none |
data storage |
|
date--hour--minute |
date--hour--minute |
date--hour--minute |
|
Storage interval or direct data transfer |
1s…3600s |
1s…3600s |
|
communication interface |
RS232 |
RS232/ USB1.1--2.0interface |
|
rangePt100(Pt1000) |
-200℃…650℃(Pt1000) |
-200℃…650℃(Pt1000) |
|
rangeNi1000--NTC |
-50℃…250℃ |
-50℃…250℃ |
|
resolution |
0.01℃±199.9℃/ 0.1℃ Other ranges |
|
|
precision |
0.01℃ |
0.01℃ |
|
1Drift after the year |
0.1℃ |
0.1℃ |
|
Number and type of input channels |
2apt100Sensors, orpt1000,Ni1000,NTC,4Line systemTP 47 |
2apt100Sensors, orpt1000,Ni1000,NTC,4Line systemTP 47 |
|
battery-powered |
4×1.5V AA |
4×1.5V AA |
|
power supply |
9V—150mA |
9V—150mA |
|
Protection level |
IP 67 |
IP 67 |
|
Size of portable case |
320×300×100 |
320×300×100 |
|
Weight, excluding probe |
1700g |
1700g |
|
Standard Configuration |
Portable case, instructions for use,4Save battery,DeltaLog 9Software; Excluding temperature probes. |
|
|
accessories |
Contact us to request information |
|