Welcome Customer !

Membership

Help

Beijing North Dahe Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products
Product Categories

Beijing North Dahe Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 913, Hongyu Building, No. 7 Xueyuan Road, Haidian District, Beijing

Contact Now

HD978TR2 thermocouple temperature transmitter

NegotiableUpdate on 10/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HD978TR2 thermocouple temperature transmitter J-K-T-N thermocouple transmitter - rail mounted thermocouple temperature transmitter input thermocouple: K, J, T, N reverse polarity protection range can be set arbitrarily, optional LCD display

Product Details

HD978TR2 transmitter outputs 4... 20mA/20... 4mA analog signal, 2-wire K, J, T, N thermocouple temperature transmitter, minimum measurement range 50 ℃, 35mm DIN rail connection, 2 modules, with digital display screen, height 10mm.

HD778TR1, HD978TR1, and HD978TR2 are passive two-wire transmitters with 4-20mA outputs for K, J, T, and N thermocouples. They convert the voltage value generated by the thermocouples into a linear current output of 4-20mA. The digital device ensures the accuracy and stability of the instrument. Users can set the output of 4-20mA (or 20-4mA) to any temperature range within the measurement range (including a single thermocouple with a minimum range of 50 ℃), and the type and range of the thermocouple can be successfully set with just one button. The indicator light indicates an alarm status (broken or no sensor connected), which helps users to make relevant settings. In addition, the transmitter is used to prevent polarity reversal. HD778TR1 can be installed on DIN B-type connectors, while HD978TR1 and HD978TR2 can be installed on 35mm DIN rails. In addition to a 4-20mA output, the HD978TR2 comes with a digital display screen (10mm high) that displays the measured temperature.


Technical Specifications:

model

HD978TR2

sensor

Thermocouple type:JKTN

connect

2Line system-Passive sensors

thermocoupleKRange of measurement

K:-200…1200

thermocoupleJRange of measurement

J:-200…800

thermocoupleTRange of measurement

T:-200…300

thermocoupleNRange of measurement

N:-200…1200

Linear standard

EN60584-1-2ASTM E 230-ANSIMC96-1

Minimum measurement range

50

conversion speed

per second2A measurement value

precision

± of reading0.004%FS±0.004%or0.5(Two values will be larger)

Cold junction temperature range

0...70

Operating Temperature

0...70

output type

2Line system4—20mA(or20 …4mA),When the sensor is damaged or not connected22mA

resolution

4µA,LCDDisplay:0.1T<200, 1.0T>200

power supply voltage

9…30Vdc(Reverse polarity protection)

VdcSensitivity of various voltages

04μA/V

load resistor

RLMAX=Vdc-9Vdc/0,022 RLMAX=625Ωcon

Vdc=24Vdcinput/ output

insulation50Vdc(250Vverify

)

31display2 /LCDDigital display (high)10mm

install35mm DIN

rail

installvolume2 DINModule(